Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.enbuild.2013.02.034
DC FieldValue
dc.titleExperimental study on partially internally cooled dehumidification in liquid desiccant air conditioning system
dc.contributor.authorGao, W.Z.
dc.contributor.authorShi, Y.R.
dc.contributor.authorCheng, Y.P.
dc.contributor.authorSun, W.Z.
dc.date.accessioned2014-06-17T07:40:46Z
dc.date.available2014-06-17T07:40:46Z
dc.date.issued2013
dc.identifier.citationGao, W.Z., Shi, Y.R., Cheng, Y.P., Sun, W.Z. (2013). Experimental study on partially internally cooled dehumidification in liquid desiccant air conditioning system. Energy and Buildings 61 : 202-209. ScholarBank@NUS Repository. https://doi.org/10.1016/j.enbuild.2013.02.034
dc.identifier.issn03787788
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/63892
dc.description.abstractThe dehumidifier is one of the essential components in air-conditioning systems with liquid desiccant. Compared with adiabatic dehumidifiers, internally cooled dehumidifiers can achieve better dehumidification performance. In this study, dehumidification effectiveness and moisture removal rate were adopted to evaluate and compare the performance of these two kinds of dehumidifiers. The results indicated that internally cooled dehumidifiers can significantly improve performance compared with adiabatic dehumidifiers, especially when the solution is at a high temperature and/or low concentration in the downstream section of the liquid desiccant flow. Performance improvement and energy saving can be taken into consideration simultaneously by only supplying cooling water to the latter part of the dehumidifier. Solution temperatures at 20-25°C for adiabatic dehumidifiers are optimal and those at 25-30 °C for internal cooled types. Lower temperatures of the cooling water can result in higher values for dehumidification effectiveness and moisture removal rate in an internally cooled dehumidifier; the limited temperature difference between cooling water and solution might seriously weaken the effect of the cooling water. Dimensionless Sherwood number Sh was calculated, and discrepancies between predicted values and experimental data are almost within ±20%. © 2013 Elsevier B.V.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.enbuild.2013.02.034
dc.sourceScopus
dc.subjectAdiabatic
dc.subjectDehumidifier
dc.subjectPartially internally cooled
dc.subjectSherwood number Sh
dc.typeArticle
dc.contributor.departmentCHEMICAL & BIOMOLECULAR ENGINEERING
dc.description.doi10.1016/j.enbuild.2013.02.034
dc.description.sourcetitleEnergy and Buildings
dc.description.volume61
dc.description.page202-209
dc.description.codenENEBD
dc.identifier.isiut000320485500025