Please use this identifier to cite or link to this item: https://doi.org/10.1049/el:20001414
Title: Circuit for microbolometer bias-heating cancellation
Authors: Xu, Y.P. 
Qian, X.B. 
Karunasiri, G. 
Issue Date: 23-Nov-2000
Citation: Xu, Y.P., Qian, X.B., Karunasiri, G. (2000-11-23). Circuit for microbolometer bias-heating cancellation. Electronics Letters 36 (24) : 1993-1994. ScholarBank@NUS Repository. https://doi.org/10.1049/el:20001414
Abstract: A new circuit for microbolometer bias-heating cancellation is described. The circuit is based on the equivalence between the electrical and thermal capacitance. A replica of the bias-heating effect is generated on the electrical capacitance and is used to effectively cancel the bias heating of the microbolometer. The cancellation is tunable.
Source Title: Electronics Letters
URI: http://scholarbank.nus.edu.sg/handle/10635/61937
ISSN: 00135194
DOI: 10.1049/el:20001414
Appears in Collections:Staff Publications