Please use this identifier to cite or link to this item:
https://doi.org/10.1016/S0967-0661(99)00198-7
DC Field | Value | |
---|---|---|
dc.title | Advanced controller auto-tuning and its application in HVAC systems | |
dc.contributor.author | Bi, Q. | |
dc.contributor.author | Cai, W.-J. | |
dc.contributor.author | Wang, Q.-G. | |
dc.contributor.author | Hang, C.-C. | |
dc.contributor.author | Eng-Lock Lee | |
dc.contributor.author | Sun, Y. | |
dc.contributor.author | Liu, K.-D. | |
dc.contributor.author | Zhang, Y. | |
dc.contributor.author | Zou, B. | |
dc.date.accessioned | 2014-06-17T06:43:53Z | |
dc.date.available | 2014-06-17T06:43:53Z | |
dc.date.issued | 2000-06 | |
dc.identifier.citation | Bi, Q., Cai, W.-J., Wang, Q.-G., Hang, C.-C., Eng-Lock Lee, Sun, Y., Liu, K.-D., Zhang, Y., Zou, B. (2000-06). Advanced controller auto-tuning and its application in HVAC systems. Control Engineering Practice 8 (6) : 633-644. ScholarBank@NUS Repository. https://doi.org/10.1016/S0967-0661(99)00198-7 | |
dc.identifier.issn | 09670661 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/61777 | |
dc.description.abstract | In this paper, an advanced PID auto-tuner for both single- and multi-variable processes is described and its application to HVAC systems is presented. The auto-tuner exploits two different process identification methods to suit a wide range of processes. It incorporates two recent PID design rules to achieve high control performances for processes with different dynamic characteristics. Decoupling control is used for multivariable processes. The auto-tuner was implemented on a distributed control system and applied in industry. Experimental results demonstrate the effectiveness and superior performance of the implemented auto-tuner over the manually tuned PID controller and the standard relay auto-tuner. (C) 2000 Elsevier Science Ltd. All rights reserved. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/S0967-0661(99)00198-7 | |
dc.source | Scopus | |
dc.subject | HVAC | |
dc.subject | Multivariable control | |
dc.subject | PID auto-tuning | |
dc.subject | Process identification | |
dc.subject | Relay feedback | |
dc.subject | Step response | |
dc.type | Article | |
dc.contributor.department | ELECTRICAL ENGINEERING | |
dc.description.doi | 10.1016/S0967-0661(99)00198-7 | |
dc.description.sourcetitle | Control Engineering Practice | |
dc.description.volume | 8 | |
dc.description.issue | 6 | |
dc.description.page | 633-644 | |
dc.description.coden | COEPE | |
dc.identifier.isiut | 000087457600003 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.