Please use this identifier to cite or link to this item: https://doi.org/10.1007/s10439-009-9664-7
DC FieldValue
dc.titleThe role of posture, magnification, and grip force on microscopic accuracy
dc.contributor.authorSafwat, B.
dc.contributor.authorSu, E.L.M.
dc.contributor.authorGassert, R.
dc.contributor.authorTeo, C.L.
dc.contributor.authorBurdet, E.
dc.date.accessioned2014-06-17T06:36:11Z
dc.date.available2014-06-17T06:36:11Z
dc.date.issued2009-05
dc.identifier.citationSafwat, B., Su, E.L.M., Gassert, R., Teo, C.L., Burdet, E. (2009-05). The role of posture, magnification, and grip force on microscopic accuracy. Annals of Biomedical Engineering 37 (5) : 997-1006. ScholarBank@NUS Repository. https://doi.org/10.1007/s10439-009-9664-7
dc.identifier.issn00906964
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/61524
dc.description.abstractWhile tremor has been studied extensively, the investigations thus far do not give detailed information on how the accuracy necessary for micromanipulations is affected while performing tasks in microsurgery and the life sciences. This paper systematically studies the effects of visual feedback, posture and grip force on the trial error and tremor intensity of subjects holding a forceps-like object to perform a pointing task. Results indicate that: (i) Arm support improves accuracy in tasks requiring fine manipulation and reduces tremor intensity in the 2-8 Hz region, but hand support does not provide the same effect; hence freedom of wrist movement can be retained without a significant increase in trial error. (ii) Magnification of up to ×10 is critical to carry out accurate micromanipulations, but beyond that level, magnification is not the most important factor. (iii) While an appropriate grip force must be learned in order to grasp micro-objects, such as a needle, without damaging them, the level of grip force applied does not affect the endpoint accuracy. © 2009 Biomedical Engineering Society.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1007/s10439-009-9664-7
dc.sourceScopus
dc.subjectAccuracy
dc.subjectGrip force
dc.subjectMagnification
dc.subjectManipulation
dc.subjectMicroscopy
dc.subjectMicrosurgery
dc.subjectPosture
dc.typeArticle
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1007/s10439-009-9664-7
dc.description.sourcetitleAnnals of Biomedical Engineering
dc.description.volume37
dc.description.issue5
dc.description.page997-1006
dc.description.codenABMEC
dc.identifier.isiut000264853800012
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.