dc.description.abstract | The design of open-cathode polymer electrolyte fuel cell (PEFC) stacks with forced-air convection from one or several fans requires careful consideration of the characteristic curves of the stack and the fan(s). Ideally, the intersection - the operating point - between the stack and the fan characteristic curves should be located in the optimal operating region of the fan; and be sufficiently far away from any unstable region. In this paper, the effect of various fan and stack configurations, operating conditions and their impact on the fan and system characteristic curves as well as stack performance are investigated with a model considering two-phase flow and conservation of mass, momentum, species, charge, and energy in the PEFC stack and ambient; the fans are treated as interface conditions. The results indicate that the fan power rating, fan type, single fan or fans in series, fuel cell length, and separate air-coolant channels have a significant impact on the operating point and resulting stack performance - these factors therefore have to be accounted for when designing the PEFC stack and selecting fans. Furthermore, the results suggest that the stack characteristic curve can be secured by straight-forward air-flow simulations instead of solving a detailed, mechanistic fuel-cell model, allowing for more efficient model-based design studies of fans interacting with a PEFC stack. © 2011 Elsevier Ltd. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.renene.2011.06.037 | |
dc.source | Scopus | |
dc.subject | Fan | |
dc.subject | Forced-air convection | |
dc.subject | Open-cathode | |
dc.subject | Polymer electrolyte fuel cell | |
dc.subject | Thermal management | |
dc.type | Article | |
dc.contributor.department | CHEMICAL & BIOMOLECULAR ENGINEERING | |
dc.contributor.department | MECHANICAL ENGINEERING | |
dc.description.doi | 10.1016/j.renene.2011.06.037 | |
dc.description.sourcetitle | Renewable Energy | |
dc.description.volume | 37 | |
dc.description.issue | 1 | |
dc.description.page | 325-332 | |
dc.identifier.isiut | 000295766000037 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.