Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.jbiomech.2011.03.031
DC FieldValue
dc.titleAn instrumented tissue tester for measuring soft tissue property under the metatarsal heads in relation to metatarsophalangeal joint angle
dc.contributor.authorChen, W.-M.
dc.contributor.authorPhyau-Wui Shim, V.
dc.contributor.authorPark, S.-B.
dc.contributor.authorLee, T.
dc.date.accessioned2014-06-17T06:11:59Z
dc.date.available2014-06-17T06:11:59Z
dc.date.issued2011-06-03
dc.identifier.citationChen, W.-M., Phyau-Wui Shim, V., Park, S.-B., Lee, T. (2011-06-03). An instrumented tissue tester for measuring soft tissue property under the metatarsal heads in relation to metatarsophalangeal joint angle. Journal of Biomechanics 44 (9) : 1801-1804. ScholarBank@NUS Repository. https://doi.org/10.1016/j.jbiomech.2011.03.031
dc.identifier.issn00219290
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/59483
dc.description.abstractIdentification of the localized mechanical response of the plantar soft tissue pads underneath the metatarsal heads (i.e., sub-MTH pad) to external loading is key to understand and predict how it functions in a gait cycle. The mechanical response depends on various parameters, such as the external load (direction and rate), the sub-MTH tissue properties (anisotropy and viscoelasticity), and the configuration of the metatarsophalangeal (MTP) joint overlying the tissue. In this study, an instrument-driven tissue tester that incorporates a portable motorized indentor within a special foot positioning apparatus was developed for realistic in vivo mechanical characterization (i.e. tissue stiffness and force relaxation behavior) of the local sub-MTH pad with the MTP joint configured at various dorsiflexion angles associated with gait. The tester yields consistent results for tests on the 2nd sub-MTH pad. Measurement errors for the initial stiffness (for indentation depths ≤1. mm), end-point stiffness, and percentage force relaxation were less than 0.084. N/mm, 0.133. N/mm, and 0.127%, respectively, across all test configurations. The end-point tissue stiffness, which increased by 104.2% due to a 50° MTP joint dorsiflexion, also agreed with a previous investigation. In vivo tissue's force relaxation was shown to be pronounced (avg.=8.1%), even for a short holding-time interval. The proposed technique to facilitate study of the dependence of the local sub-MTH pad and tissue response on the MTP joint angle might be preferable to methods that focus solely on measurement of tissue property because under physiologic conditions the sub-MTH pad elasticity may vary in gait, to adapt to drastically changing mechanical demands in the sub-MTH region of the terminal stance-phase, where MTP joint dorsiflexion occurs. © 2011 Elsevier Ltd.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.jbiomech.2011.03.031
dc.sourceScopus
dc.subjectFoot
dc.subjectLocalized mechanical response
dc.subjectMetatarsal head
dc.subjectMetatarsophalangeal joint
dc.subjectSoft-tissue pad
dc.typeArticle
dc.contributor.departmentBIOENGINEERING
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1016/j.jbiomech.2011.03.031
dc.description.sourcetitleJournal of Biomechanics
dc.description.volume44
dc.description.issue9
dc.description.page1801-1804
dc.description.codenJBMCB
dc.identifier.isiut000291846300028
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

SCOPUSTM   
Citations

14
checked on Aug 6, 2020

WEB OF SCIENCETM
Citations

12
checked on Jul 30, 2020

Page view(s)

90
checked on Aug 3, 2020

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.