Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.buildenv.2011.04.021
DC FieldValue
dc.titleAssessment of airborne bacteria and fungi in food courts
dc.contributor.authorRajasekar, A.
dc.contributor.authorBalasubramanian, R.
dc.date.accessioned2014-06-17T05:28:58Z
dc.date.available2014-06-17T05:28:58Z
dc.date.issued2011-10
dc.identifier.citationRajasekar, A., Balasubramanian, R. (2011-10). Assessment of airborne bacteria and fungi in food courts. Building and Environment 46 (10) : 2081-2087. ScholarBank@NUS Repository. https://doi.org/10.1016/j.buildenv.2011.04.021
dc.identifier.issn03601323
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/58961
dc.description.abstractA study was undertaken to determine the effect of variations in temperature, relative humidity, occupancy density and location (indoor/outdoor) on the concentrations of viable airborne bacterial and fungal spores at an air-conditioned and a non air-conditioned food stall in Singapore. Typically, bioaerosols consisted of 50.5% bacteria and 49.5% fungi in the indoor environment. In contrast, for the outdoor environment, bacteria on an average only accounted for 20.6% of culturable airborne microorganisms whereas fungal concentrations were 79.4%. Results on bioaerosol size distributions revealed that 67% of indoor bacteria and 68% of outdoor bacteria, 85% of indoor fungi and 68% of outdoor fungi were associated with fine mode particulates (<3.3 μm). Occupant density was the key factor that affected indoor airborne bacteria concentrations while concentrations of outdoor airborne bacteria depended strongly on ambient temperature. Indoor fungal concentration was positively correlated to relative humidity whereas outdoor fungal concentration was positively correlated to relative humidity and negatively correlated to temperature. The study also compared the biological air quality between a non air-conditioned food stall (Stall A) and an air-conditioned food stall (Stall B). The dining area of the former had lower bacterial concentrations as compared to the latter, while fungal spore's concentrations showed a reverse trend. The dominant airborne bacteria genera were Staphylococcus, Pseudomonas, Alcaligens, and Corynebacterium whereas Penicillium, Aspergillus and Cladosporium were the most common fungal genera and groups in both food stalls. © 2011 Elsevier Ltd.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.buildenv.2011.04.021
dc.sourceScopus
dc.subjectAirborne microbes
dc.subjectBacteria
dc.subjectBioaerosols
dc.subjectFungi
dc.subjectIndoor air quality
dc.subjectSize distribution
dc.typeArticle
dc.contributor.departmentCIVIL & ENVIRONMENTAL ENGINEERING
dc.description.doi10.1016/j.buildenv.2011.04.021
dc.description.sourcetitleBuilding and Environment
dc.description.volume46
dc.description.issue10
dc.description.page2081-2087
dc.description.codenBUEND
dc.identifier.isiut000292223900024
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.