Please use this identifier to cite or link to this item: https://doi.org/10.1016/0142-9612(93)90142-O
DC FieldValue
dc.titleEffect of pore sizes and cholesterol-lipid solution on the fracture toughness of pure titanium sintered compacts
dc.contributor.authorTeoh, S.H.
dc.contributor.authorThampuran, R.
dc.contributor.authorSeah, W.K.H.
dc.contributor.authorGoh, J.C.H.
dc.date.accessioned2014-06-17T05:11:48Z
dc.date.available2014-06-17T05:11:48Z
dc.date.issued1993-05
dc.identifier.citationTeoh, S.H., Thampuran, R., Seah, W.K.H., Goh, J.C.H. (1993-05). Effect of pore sizes and cholesterol-lipid solution on the fracture toughness of pure titanium sintered compacts. Biomaterials 14 (6) : 407-412. ScholarBank@NUS Repository. https://doi.org/10.1016/0142-9612(93)90142-O
dc.identifier.issn01429612
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/58187
dc.description.abstractCommercial pure titanium has been widely used as an implant material because of its excellent biocompatibility and good ductility. To determine the effect of pore size on the fracture resistance of porous titanium compacts, a series of fracture toughness (K(Q)) tests were performed on commercial pure titanium powder compacted to 017 and 0.62 GPa. Pore sizes ranged from 25 to 103 μm, with porosity between 8.5 and 35%. Two sets of fracture toughness tests using disc-shaped compacts (ASTM E 399-90) were performed, the first in air at 37°C and the second with compacts treated in cholesterol-lipid solution at 37°C. The K(Q) value of compacts with a smaller mean pore size (ca. 50 μm) was approximately twice that of the compacts with a larger mean pore size (100 μm). The effect of cholesterol-lipid solution treatment was detrimental, perhaps due to preferential lipid absorption by the titanium oxide and/or the presence of chlorides. For the smaller pore size compacts, the K(Q) values decreased by up to 20%. For the larger pore size compacts, the effect of cholesterol-lipid solution was less significant. Morphologically, compacts with smaller pore size had a predominantly ductile fracture with significantly higher dimple density than the larger pore size compacts.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/0142-9612(93)90142-O
dc.sourceScopus
dc.subjectFracture properties
dc.subjectPore size
dc.subjectSintering
dc.subjectTitanium compact
dc.typeArticle
dc.contributor.departmentORTHOPAEDIC SURGERY
dc.contributor.departmentMECHANICAL & PRODUCTION ENGINEERING
dc.description.doi10.1016/0142-9612(93)90142-O
dc.description.sourcetitleBiomaterials
dc.description.volume14
dc.description.issue6
dc.description.page407-412
dc.description.codenBIMAD
dc.identifier.isiutA1993LC03500002
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.