Please use this identifier to cite or link to this item: https://doi.org/10.1109/TMI.2007.892643
DC FieldValue
dc.titleNew insights into image processing of cortical blood flow monitors using laser speckle imaging
dc.contributor.authorLe, T.M.
dc.contributor.authorPaul, J.S.
dc.contributor.authorAl-Nashash, H.
dc.contributor.authorTan, A.
dc.contributor.authorLuft, A.R.
dc.contributor.authorSheu, F.S.
dc.contributor.authorOng, S.H.
dc.date.accessioned2014-06-17T02:58:44Z
dc.date.available2014-06-17T02:58:44Z
dc.date.issued2007-06
dc.identifier.citationLe, T.M., Paul, J.S., Al-Nashash, H., Tan, A., Luft, A.R., Sheu, F.S., Ong, S.H. (2007-06). New insights into image processing of cortical blood flow monitors using laser speckle imaging. IEEE Transactions on Medical Imaging 26 (6) : 833-842. ScholarBank@NUS Repository. https://doi.org/10.1109/TMI.2007.892643
dc.identifier.issn02780062
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/56799
dc.description.abstractLaser speckle imaging has increasingly become a viable technique for real-time medical imaging. However, the computational intricacies and the viewing experience involved limit its usefulness for real-time monitors such as those intended for neurosurgical applications. In this paper, we propose a new technique, tLASCA, which processes statistics primarily in the temporal direction using the laser speckle contrast analysis (LASCA) equation, proposed by Briers and Webster. This technique is thoroughly compared with the existing techniques for signal processing of laser speckle images, including, the spatial-based sLASCA and the temporal-based modified laser speckle imaging (mLSI) techniques. sLASCA is an improvement of the basic LASCA technique. In sLASCA, the derived contrasts are further averaged over a predetermined number of raw speckle images. mLSI, on the other hand, is the technique in which temporal statistics are processed using the equation described by Ohtsubo and Asakura. tLASCA preserves the original image resolution similar to mLSI. tLASCA outperforms sLASCA (window size M = 5) with faster convergence of K values (5.32 versus 20.56 s), shorter per-frame processing time (0.34 versus 2.51 s), and better subjective and objective quality evaluations of contrast images. tLASCA also outperforms mLSI with faster convergence of K values (5.32 s) compared to N values (10.44 s), shorter per-frame processing time (0.34 versus 0.91 s), smaller intensity fluctuations among frames (8%-10% versus 15%-35%), and better subjective and objective quality evaluations of contrast images. As laser speckle imaging becomes an important tool for real-time monitoring of blood flows and vascular perfusion, tLASCA is proven to be the technique of choice. © 2007 IEEE.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/TMI.2007.892643
dc.sourceScopus
dc.subjectBlood flow and perfusion
dc.subjectLaser speckle imaging
dc.subjectMedical image processing
dc.subjectSubjective and objective quality
dc.subjectTime-varying speckle
dc.typeArticle
dc.contributor.departmentELECTRICAL & COMPUTER ENGINEERING
dc.contributor.departmentBIOLOGICAL SCIENCES
dc.description.doi10.1109/TMI.2007.892643
dc.description.sourcetitleIEEE Transactions on Medical Imaging
dc.description.volume26
dc.description.issue6
dc.description.page833-842
dc.description.codenITMID
dc.identifier.isiut000247016400008
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.