Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.cmpb.2004.06.003
DC FieldValue
dc.titleComputer-based extraction of the inferior alveolar nerve canal in 3-D space
dc.contributor.authorKondo, T.
dc.contributor.authorOng, S.H.
dc.contributor.authorFoong, K.W.C.
dc.date.accessioned2014-06-17T02:42:29Z
dc.date.available2014-06-17T02:42:29Z
dc.date.issued2004-12
dc.identifier.citationKondo, T., Ong, S.H., Foong, K.W.C. (2004-12). Computer-based extraction of the inferior alveolar nerve canal in 3-D space. Computer Methods and Programs in Biomedicine 76 (3) : 181-191. ScholarBank@NUS Repository. https://doi.org/10.1016/j.cmpb.2004.06.003
dc.identifier.issn01692607
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/55386
dc.description.abstractComputed tomography (CT) is increasingly employed in orthodontic treatment. One of the most successful applications is in dental implantology, in which an artificial root is surgically inserted into the jawbone to provide anchorage for a dental prosthesis. For successful implant surgery, it is crucial to locate internal structures such as the inferior alveolar nerve canal (IAC). This paper presents a computerized technique for extracting the IAC. To facilitate the extraction, we first generate panoramic CT images (panoramics) by reformatting the original CT images. The panoramics are a series of cross-sectional images along curved planes through the mandible (lower jawbone). Hollow canals are subsequently detected by analyzing the voxel intensities and 3-D gradient orientations in the panoramics. The axis of the IAC is then traced out by a novel 3-D line-tracking technique. The method is effective for extracting the IAC despite the open structure of the surrounding bone. © 2004 Elsevier Ireland Ltd. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.cmpb.2004.06.003
dc.sourceScopus
dc.subjectCT
dc.subjectDental implantology
dc.subjectGradient orientation analysis
dc.subjectIAC
dc.subjectLine tracking
dc.typeArticle
dc.contributor.departmentPREVENTIVE DENTISTRY
dc.contributor.departmentELECTRICAL & COMPUTER ENGINEERING
dc.description.doi10.1016/j.cmpb.2004.06.003
dc.description.sourcetitleComputer Methods and Programs in Biomedicine
dc.description.volume76
dc.description.issue3
dc.description.page181-191
dc.description.codenCMPBE
dc.identifier.isiut000225120700001
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.