Please use this identifier to cite or link to this item: https://doi.org/10.1109/TBME.2012.2190511
DC FieldValue
dc.titleA multiscale model for bioimpedance dispersion of liver tissue
dc.contributor.authorHuang, W.H.
dc.contributor.authorChui, C.K.
dc.contributor.authorTeoh, S.H.
dc.contributor.authorChang, S.K.Y.
dc.date.accessioned2014-06-16T09:31:30Z
dc.date.available2014-06-16T09:31:30Z
dc.date.issued2012
dc.identifier.citationHuang, W.H., Chui, C.K., Teoh, S.H., Chang, S.K.Y. (2012). A multiscale model for bioimpedance dispersion of liver tissue. IEEE Transactions on Biomedical Engineering 59 (6) : 1593-1597. ScholarBank@NUS Repository. https://doi.org/10.1109/TBME.2012.2190511
dc.identifier.issn00189294
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/54472
dc.description.abstractRadio-frequency ablation (RFA) has been used in liver surgery to minimize blood loss during tissue division. However, the current RFA tissue division method lacks an effective way of determining the stoppage of blood flow. There is limitation on the current state-of-the-art laser Doppler flow sensor due to its small sensing area. A new technique was proposed to use bioimpedance for blood flow sensing. This paper discusses a new geometrical multiscale model of the liver bioimpedance incorporating blood flow impedance. This model establishes correlation between the physical tissue structure and bioimpedance measurement. The basic Debye structure within a multilevel framework is used in the model to account for bioimpedance dispersion. This dispersion is often explained by the Cole-Cole model that includes a constant phase element without physical explanation. Our model is able to account for reduced blood flow in its output with changes in permittivity in gamma dispersion that is mainly due to the polarization of water molecules. This study demonstrates the potential of a multiscale model in determining the stoppage of blood flow during surgery. © 1964-2012 IEEE.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/TBME.2012.2190511
dc.sourceScopus
dc.subjectBioimpedance
dc.subjectblood flow
dc.subjectdispersion
dc.subjectliver
dc.subjectmultiscale model
dc.subjectradio-frequency ablation (RFA)
dc.subjectsurgery
dc.typeArticle
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1109/TBME.2012.2190511
dc.description.sourcetitleIEEE Transactions on Biomedical Engineering
dc.description.volume59
dc.description.issue6
dc.description.page1593-1597
dc.description.codenIEBEA
dc.identifier.isiut000304242700011
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.