Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.cag.2011.07.007
DC FieldValue
dc.titleA geometric approach to the modeling of the catheterheart interaction for VR simulation of intra-cardiac intervention
dc.contributor.authorChiang, P.
dc.contributor.authorCai, Y.
dc.contributor.authorMak, K.H.
dc.contributor.authorSoe, E.M.
dc.contributor.authorChui, C.K.
dc.contributor.authorZheng, J.
dc.date.accessioned2014-06-16T09:28:48Z
dc.date.available2014-06-16T09:28:48Z
dc.date.issued2011-10
dc.identifier.citationChiang, P., Cai, Y., Mak, K.H., Soe, E.M., Chui, C.K., Zheng, J. (2011-10). A geometric approach to the modeling of the catheterheart interaction for VR simulation of intra-cardiac intervention. Computers and Graphics (Pergamon) 35 (5) : 1013-1022. ScholarBank@NUS Repository. https://doi.org/10.1016/j.cag.2011.07.007
dc.identifier.issn00978493
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/54217
dc.description.abstractCardiac intervention is a minimally invasive diagnostic and therapeutic procedure used to treat cardiac diseases. The mapping of heart geometry with minimal visual assistance presents a technical challenge for interventional cardiologists attempting catheter navigation. This paper presents a geometric approach to modeling the catheterheart interaction for VR simulations of catheter navigation within a heart chamber. Three types of modeling are used to model the interaction between the catheter and the heart wall: non-slip, pseudo-slip and slip modeling. A two-step shape memory process that minimizes the bending of and strain on the catheter is designed for catheter deformation for non-slip or pseudo-slip contact, and a progressive group linkage bending process that constrains the catheter curvature and position within the volume enclosure is designed for catheter deformation for slip contact. The proposed model is consistent with the observations made during the experiment. The model is able to deform the catheter in any free-state shape within the volume enclosure and is independent of local motion increment. Thus, it presents advantages in terms of complexity and real-time requirements. © 2011 Elsevier Ltd. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.cag.2011.07.007
dc.sourceScopus
dc.subjectCatheter deformation
dc.subjectCatheterheart interaction
dc.subjectIntra-cardiac intervention
dc.subjectVR simulation
dc.typeArticle
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.1016/j.cag.2011.07.007
dc.description.sourcetitleComputers and Graphics (Pergamon)
dc.description.volume35
dc.description.issue5
dc.description.page1013-1022
dc.description.codenCOGRD
dc.identifier.isiut000295769600007
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.