Please use this identifier to cite or link to this item:
https://doi.org/10.1016/j.ajo.2011.01.018
DC Field | Value | |
---|---|---|
dc.title | Influence of refractive error on optic disc topographic parameters: The Singapore malay eye study | |
dc.contributor.author | Wu, R.-Y. | |
dc.contributor.author | Wong, T.-Y. | |
dc.contributor.author | Zheng, Y.-F. | |
dc.contributor.author | Cheung, C.Y.-L. | |
dc.contributor.author | Perera, S.A. | |
dc.contributor.author | Saw, S.M. | |
dc.contributor.author | Aung, T. | |
dc.date.accessioned | 2014-05-20T02:29:41Z | |
dc.date.available | 2014-05-20T02:29:41Z | |
dc.date.issued | 2011-07 | |
dc.identifier.citation | Wu, R.-Y., Wong, T.-Y., Zheng, Y.-F., Cheung, C.Y.-L., Perera, S.A., Saw, S.M., Aung, T. (2011-07). Influence of refractive error on optic disc topographic parameters: The Singapore malay eye study. American Journal of Ophthalmology 152 (1) : 81-86. ScholarBank@NUS Repository. https://doi.org/10.1016/j.ajo.2011.01.018 | |
dc.identifier.issn | 00029394 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/53450 | |
dc.description.abstract | Purpose: To examine the relationship between refractive error and optic disc topographic parameters and retinal nerve fiber layer (RNFL) thickness. Design: Population-based cross-sectional study. Methods: All 3280 (78.7% response rate) persons of Asian Malay ethnicity 40 to 80 years of age underwent a standardized interview, ocular examinations, and optic disc imaging with the Heidelberg Retina Tomography II (HRT; Heidelberg Engineering). Associations between spherical equivalent (SE) and HRT parameters were evaluated by partial correlation analysis. Results: There were 2457 (74.9%) right eyes with good-quality HRT images for analyses. When compared with emmetropic eyes, highly myopic eyes (SE < -6.0 diopters) had greater disc area, rim area, rim volume, whereas hyperopic eyes (SE > 0.5 diopters) had significantly smaller disc area, rim area, and cross-sectional RNFL area (all P < .005). In partial correlation after adjustment for age, sex, body mass index, intraocular pressure, and optic disc area, increase of SE (toward hyperopia) was related significantly with greater cup area (partial correlation coefficient, r = 0.058; P = .004) and cup-to-disc area ratio (r = 0.058; P = .004) and with smaller optic disc area (r = -0.058; P = .004), rim area (r = 0.058; P = .004), and rim volume (r = -0.091; P < .001). Conclusions: This population-based study shows that refractive error is significantly (but weakly) associated with HRT parameters of disc area, cup area, rim area, cup-to-disc area ratio, and rim volume. The clinical significance of these associations need to be determined in further studies. © 2011 Elsevier Inc. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.ajo.2011.01.018 | |
dc.source | Scopus | |
dc.type | Article | |
dc.contributor.department | OPHTHALMOLOGY | |
dc.contributor.department | EPIDEMIOLOGY & PUBLIC HEALTH | |
dc.description.doi | 10.1016/j.ajo.2011.01.018 | |
dc.description.sourcetitle | American Journal of Ophthalmology | |
dc.description.volume | 152 | |
dc.description.issue | 1 | |
dc.description.page | 81-86 | |
dc.description.coden | AJOPA | |
dc.identifier.isiut | 000292490500014 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.