Please use this identifier to cite or link to this item: https://scholarbank.nus.edu.sg/handle/10635/52993
DC FieldValue
dc.titleInfluence of curing lights and modes on cross-link density of dental composites
dc.contributor.authorYap, A.U.J.
dc.contributor.authorSoh, M.S.
dc.contributor.authorHan, V.T.S.
dc.contributor.authorSiow, K.S.
dc.date.accessioned2014-05-19T02:52:46Z
dc.date.available2014-05-19T02:52:46Z
dc.date.issued2004-07
dc.identifier.citationYap, A.U.J.,Soh, M.S.,Han, V.T.S.,Siow, K.S. (2004-07). Influence of curing lights and modes on cross-link density of dental composites. Operative Dentistry 29 (4) : 410-415. ScholarBank@NUS Repository.
dc.identifier.issn03617734
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/52993
dc.description.abstractThis study investigated the influence of curing lights and modes on the cross-link density of dental composites. Four LED/halogen curing lights (LED-Elipar Freelight [FL], 3M-ESPE and GC e-light [EL], GC; high intensity halogen-Elipar Trilight [TL], 3M-ESPE; very high intensity halogen-Astralis 10 [AS], Ivoclar Vivadent) were selected for this study. Pulse (EL1), continuous (FL1, EL2, TL1), turbo (EL3, AS) and soft-start (FL2, EL4, TL2) curing modes of the various lights were examined. A conventional, continuous cure halogen light (Max [MX], Dentsply-Caulk) was used for comparison. Six composite (Z100, 3M-ESPE) specimens were made for each light-curing mode combination. After polymerization, the specimens were stored in air at 37°C for 24 hours and subjected to hardness testing using a digital microhardness tester (load=500g; dwell time=15 seconds). The specimens were then placed in 75% ethanol-water solution at 37°C for 24 hours and post-conditioning hardness was determined. Mean hardness (HK)/change in hardness (ΔHK) was computed and the data subjected to analysis using one-way ANOVA/Scheffe's test and Independent Samples t-test (p<0.05). Softening upon storage in ethanol (ΔHK) was used as a relative indication of cross-link density. Specimens polymerized with AS, TL2 and all modes of both LED lights were significantly more susceptible to softening in ethanol than specimens cured with MX. No significant difference in cross-link density was observed among the various modes of EL and FL. For TL, curing with continuous mode resulted in specimens with significantly higher cross-link density than curing with the soft-start mode.
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentRESTORATIVE DENTISTRY
dc.contributor.departmentCHEMISTRY
dc.description.sourcetitleOperative Dentistry
dc.description.volume29
dc.description.issue4
dc.description.page410-415
dc.identifier.isiutNOT_IN_WOS
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.