Please use this identifier to cite or link to this item: https://doi.org/10.1080/10611860802582442
DC FieldValue
dc.titleCritical parameters in the pegylation of gold nanoshells for biomedical applications: An in vitro macrophage study
dc.contributor.authorKah, J.C.Y.
dc.contributor.authorWong, K.Y.
dc.contributor.authorNeoh, K.G.
dc.contributor.authorSong, J.H.
dc.contributor.authorFu, J.W.P.
dc.contributor.authorMhaisalkar, S.
dc.contributor.authorOlivo, M.
dc.contributor.authorSheppard, C.J.R.
dc.date.accessioned2014-04-25T09:03:54Z
dc.date.available2014-04-25T09:03:54Z
dc.date.issued2009-04
dc.identifier.citationKah, J.C.Y., Wong, K.Y., Neoh, K.G., Song, J.H., Fu, J.W.P., Mhaisalkar, S., Olivo, M., Sheppard, C.J.R. (2009-04). Critical parameters in the pegylation of gold nanoshells for biomedical applications: An in vitro macrophage study. Journal of Drug Targeting 17 (3) : 181-193. ScholarBank@NUS Repository. https://doi.org/10.1080/10611860802582442
dc.identifier.issn1061186X
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/51768
dc.description.abstractPegylation of gold nanoshells provides an effective means to reduce their reticuloendothelial system (RES) clearance in body. In this study, we perform a parametric investigation on the factors that would affect the macrophage uptake of gold nanoshells with the aim to optimize their pegylation and minimize their macrophage uptake. We synthesized and pegylated the gold nanoshells using methoxy-poly(ethylene glycol)-thiol and employed an in vitro macrophage assay to examine the effect of surface density of poly(ethylene glycol) (PEG), chain length of the PEG, and size of the gold nanoshells on their macrophage uptake. We have shown that a saturated surface density would minimize macrophage uptake, which could be obtained by experimental titration-based Ellman's reagent. Our results suggest that the chain length of PEG and size of gold nanoshells influence the surface density of PEG. We have also shown that PEG with molecular weight of around 2000 Da and a size range larger than 186 nm would be appropriate for facilitating a high surface density. Our in vitro macrophage system thus provides a good model to accurately predict the RES response to different pegylation parameters. © 2009 Informa UK Ltd.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1080/10611860802582442
dc.sourceScopus
dc.subjectGold nanoshells
dc.subjectMacrophage uptake
dc.subjectPegylation
dc.subjectPoly(ethylene glycol)
dc.subjectRES clearance
dc.subjectReticuloendothelial system
dc.subjectSurface density
dc.typeArticle
dc.contributor.departmentBIOENGINEERING
dc.contributor.departmentPHARMACY
dc.contributor.departmentCHEMICAL & BIOMOLECULAR ENGINEERING
dc.description.doi10.1080/10611860802582442
dc.description.sourcetitleJournal of Drug Targeting
dc.description.volume17
dc.description.issue3
dc.description.page181-193
dc.description.codenJDTAE
dc.identifier.isiut000266593400001
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.