Please use this identifier to cite or link to this item:
https://doi.org/10.1109/ICIEA.2011.5975564
DC Field | Value | |
---|---|---|
dc.title | Lens image registration for cataract detection | |
dc.contributor.author | Li, H. | |
dc.contributor.author | Gao, X. | |
dc.contributor.author | Tan, M.H. | |
dc.contributor.author | Chow, Y.C. | |
dc.contributor.author | Lim, J.H. | |
dc.contributor.author | Sun, Y. | |
dc.contributor.author | Cheung, C.C. | |
dc.contributor.author | Wong, T.Y. | |
dc.date.accessioned | 2014-04-24T08:36:10Z | |
dc.date.available | 2014-04-24T08:36:10Z | |
dc.date.issued | 2011 | |
dc.identifier.citation | Li, H.,Gao, X.,Tan, M.H.,Chow, Y.C.,Lim, J.H.,Sun, Y.,Cheung, C.C.,Wong, T.Y. (2011). Lens image registration for cataract detection. Proceedings of the 2011 6th IEEE Conference on Industrial Electronics and Applications, ICIEA 2011 : 132-135. ScholarBank@NUS Repository. <a href="https://doi.org/10.1109/ICIEA.2011.5975564" target="_blank">https://doi.org/10.1109/ICIEA.2011.5975564</a> | |
dc.identifier.isbn | 9781424487554 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/51199 | |
dc.description.abstract | Cataract is the leading cause of blindness worldwide. In this paper, registration of retroillumination image is investigated for detection of cortical and posterior subcapsular cataract (PSC). The pupil region is detected by local entropy filtering. The anterior image and posterior image are registered using maximum normalized cross-correlation. The registration of anterior and posterior image can be used to detect opacity in the future. The proposed algorithms were tested using clinical data and the experimental results indicate that the proposed method could facilitate automatic cataract diagnosis. © 2011 IEEE. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/ICIEA.2011.5975564 | |
dc.source | Scopus | |
dc.subject | cataract diagnosis | |
dc.subject | image registration | |
dc.subject | retroillumination image | |
dc.type | Conference Paper | |
dc.contributor.department | OPHTHALMOLOGY | |
dc.contributor.department | ELECTRICAL & COMPUTER ENGINEERING | |
dc.description.doi | 10.1109/ICIEA.2011.5975564 | |
dc.description.sourcetitle | Proceedings of the 2011 6th IEEE Conference on Industrial Electronics and Applications, ICIEA 2011 | |
dc.description.page | 132-135 | |
dc.identifier.isiut | NOT_IN_WOS | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.