Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.enbuild.2004.08.004
DC FieldValue
dc.titleEffects of double glazed facade on energy consumption, thermal comfort and condensation for a typical office building in Singapore
dc.contributor.authorHien, W.N.
dc.contributor.authorLiping, W.
dc.contributor.authorChandra, A.N.
dc.contributor.authorPandey, A.R.
dc.contributor.authorXiaolin, W.
dc.date.accessioned2013-10-14T04:36:43Z
dc.date.available2013-10-14T04:36:43Z
dc.date.issued2005
dc.identifier.citationHien, W.N., Liping, W., Chandra, A.N., Pandey, A.R., Xiaolin, W. (2005). Effects of double glazed facade on energy consumption, thermal comfort and condensation for a typical office building in Singapore. Energy and Buildings 37 (6) : 563-572. ScholarBank@NUS Repository. https://doi.org/10.1016/j.enbuild.2004.08.004
dc.identifier.issn03787788
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/45644
dc.description.abstractFully glazed facade that has been increasingly used in Singapore causes higher energy consumption and thermal discomfort due to higher solar gain. The use of double glazed facade system with ventilation system is one way to solve these problems. The objective of this paper is to investigate the effects of double glazed facade with ventilation system on the energy consumption, thermal comfort and condensation and compare to single glazed facade system. TAS and CFD software were utilized to calculate energy consumption, thermal comfort and condensation for single glazed facade building as well as double glazed facade building. The simulation results showed double glazed facade with natural ventilation were able to minimize energy consumption as well as to enhance the thermal comfort. Turning the mechanical fans on could also solve the condensation problem due to high humidity. © 2005 Elsevier B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.enbuild.2004.08.004
dc.sourceScopus
dc.subjectCFD simulation
dc.subjectDouble glazed facade
dc.subjectTAS
dc.typeArticle
dc.contributor.departmentBUILDING
dc.description.doi10.1016/j.enbuild.2004.08.004
dc.description.sourcetitleEnergy and Buildings
dc.description.volume37
dc.description.issue6
dc.description.page563-572
dc.description.codenENEBD
dc.identifier.isiut000227978300002
Appears in Collections:Staff Publications