Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.buildenv.2005.06.003
DC FieldValue
dc.titleA study of perceived air quality and sick building syndrome in a field environment chamber served by displacement ventilation system in the tropics
dc.contributor.authorCheong, K.W.D.
dc.contributor.authorYu, W.J.
dc.contributor.authorTham, K.W.
dc.contributor.authorSekhar, S.C.
dc.contributor.authorKosonen, R.
dc.date.accessioned2013-10-14T04:34:20Z
dc.date.available2013-10-14T04:34:20Z
dc.date.issued2006
dc.identifier.citationCheong, K.W.D., Yu, W.J., Tham, K.W., Sekhar, S.C., Kosonen, R. (2006). A study of perceived air quality and sick building syndrome in a field environment chamber served by displacement ventilation system in the tropics. Building and Environment 41 (11) : 1530-1539. ScholarBank@NUS Repository. https://doi.org/10.1016/j.buildenv.2005.06.003
dc.identifier.issn03601323
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/45554
dc.description.abstractThis paper presents a study of Perceived Air Quality (PAQ) and Sick Building Syndrome (SBS) using tropically acclimatized subjects in a Field Environmental Chamber (FEC) served by Displacement Ventilation (DV) system. The FEC, 11.12 m (L)×7.53 m (W)×2.60 m (H), simulates a typical office layout. A total of 60 subjects, 30 males and 30 females, were engaged in sedentary office work for 3 h. Air velocity in the space near the subjects was kept at below 0.2 m/s. Relative Humidity (RH) at 0.6 m height and outdoor air provision were maintained at 50% and 10 l/s/p, respectively. Subjects were exposed to three vertical air temperature gradients, nominally 1, 3 and 5 K/m, between 0.1 and 1.1 m heights and three room air temperatures 20, 23 and 26 °C at 0.6 m height. The main objective of this study is to evaluate the influence of temperature gradient and room air temperature (at 0.6 m height) on PAQ and SBS in DV environment. It was found that temperature gradient had insignificant impact on PAQ and SBS. Dry air sensation, irritations and air freshness decreased with increase of room air temperature. © 2005 Elsevier Ltd. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.buildenv.2005.06.003
dc.sourceScopus
dc.subjectDisplacement ventilation
dc.subjectPerceived air quality
dc.subjectSick building syndrome
dc.subjectThermal gradient
dc.subjectTropics
dc.typeArticle
dc.contributor.departmentBUILDING
dc.description.doi10.1016/j.buildenv.2005.06.003
dc.description.sourcetitleBuilding and Environment
dc.description.volume41
dc.description.issue11
dc.description.page1530-1539
dc.description.codenBUEND
dc.identifier.isiut000239130100010
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.