Please use this identifier to cite or link to this item: https://doi.org/10.1016/S0010-7824(96)00275-2
DC FieldValue
dc.titleClinical performance of a new two-rod levonorgestrel contraceptive implant: A three-year randomized study with Norplant® implants as controls
dc.contributor.authorSivin, I.
dc.contributor.authorStern, J.
dc.contributor.authorViegas, O.
dc.contributor.authorCampodonico, I.
dc.contributor.authorDiaz, S.
dc.contributor.authorPavez, M.
dc.contributor.authorWan, L.
dc.contributor.authorKoetsawang, S.
dc.contributor.authorKiriwat, O.
dc.contributor.authorPiya, Anant M.
dc.contributor.authorHolma, P.
dc.contributor.authorEl, Din Abdalla K.
dc.date.accessioned2013-04-10T03:02:35Z
dc.date.available2013-04-10T03:02:35Z
dc.date.issued1997
dc.identifier.citationSivin, I., Stern, J., Viegas, O., Campodonico, I., Diaz, S., Pavez, M., Wan, L., Koetsawang, S., Kiriwat, O., Piya, Anant M., Holma, P., El, Din Abdalla K. (1997). Clinical performance of a new two-rod levonorgestrel contraceptive implant: A three-year randomized study with Norplant® implants as controls. Contraception 55 (2) : 73-80. ScholarBank@NUS Repository. https://doi.org/10.1016/S0010-7824(96)00275-2
dc.identifier.issn00107824
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/37141
dc.description.abstractIn a randomized three-year clinical trial at seven clinics, the performance of levonorgestrel rod (LNG ROD) implants used by 600 women was compared with that of soft tubing NORPLANT implants used by 598 women. No pregnancies occurred in either group of women and, accordingly, body weight did not affect the efficacy of either type of implant. There were neither statistically significant nor important differences in termination rates for any reason over the three years. Complaint and illness rates during use of either of the two implant types were statistically indistinguishable and were attributable to the same set of conditions. Seventy-one per 100 of the women using each implant regimen continued to the three-year point, for an average annual continuation rate of 89 per 100. Removals of LNG ROD implants were accomplished in about half the time required for removal of Norplant capsule implants (p < 0.001).
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/S0010-7824(96)00275-2
dc.sourceScopus
dc.subjectconcomitant adverse effects
dc.subjectefficacy
dc.subjectimplant contraception
dc.subjectlevonorgestrel rod
dc.subjectremovals
dc.typeArticle
dc.contributor.departmentOBSTETRICS & GYNAECOLOGY
dc.description.doi10.1016/S0010-7824(96)00275-2
dc.description.sourcetitleContraception
dc.description.volume55
dc.description.issue2
dc.description.page73-80
dc.description.codenCCPTA
dc.identifier.isiutA1997WM95200003
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.