Please use this identifier to cite or link to this item:
https://doi.org/10.1016/0378-4347(94)00458-H
DC Field | Value | |
---|---|---|
dc.title | Determination of serum aluminium using an ion-pair reversed-phase high-performance liquid chromatographic-fluorimetric system with lumogallion | |
dc.contributor.author | Wu, J. | |
dc.contributor.author | Zhou, C.Y. | |
dc.contributor.author | Chi, H. | |
dc.contributor.author | Wong, M.K. | |
dc.contributor.author | Lee, H.K. | |
dc.contributor.author | Ong, H.Y. | |
dc.contributor.author | Ong, C.N. | |
dc.date.accessioned | 2012-04-02T07:03:27Z | |
dc.date.available | 2012-04-02T07:03:27Z | |
dc.date.issued | 1995 | |
dc.identifier.citation | Wu, J., Zhou, C.Y., Chi, H., Wong, M.K., Lee, H.K., Ong, H.Y., Ong, C.N. (1995). Determination of serum aluminium using an ion-pair reversed-phase high-performance liquid chromatographic-fluorimetric system with lumogallion. Journal of Chromatography B: Biomedical Applications 663 (2) : 247-253. ScholarBank@NUS Repository. https://doi.org/10.1016/0378-4347(94)00458-H | |
dc.identifier.issn | 15726495 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/32048 | |
dc.description.abstract | An ion-pair reversed-phase high-performance liquid chromatographic method with fluorimetric detection, using lumogallion [4-chloro-3-(2,4-dihydroxyphenylazo)-2-hydroxybenzene-1-sulphonic acid] as a ligand, has been successfully applied to the determination of aluminium in human serum. The highly fluorescent aluminium-lumogallion complex (λ(ex) 505 nm, λ(em) 574 nm) was separated on a LiChrosorb RP-18 column with an eluent consisting of 30% acetonitrile, 70% 0.02 M potassium hydrogen phthalate and 10 μM lumogallion. The proposed system offers a simple, rapid, selective and sensitive method for the determination of aluminium in serum. The detection limit for aluminium was 0.05 μg/l in aqueous solution and the limit of determination was 2.2 μg/l in serum. The recovery of the method is generally over 90%. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/0378-4347(94)00458-H | |
dc.source | Scopus | |
dc.type | Article | |
dc.contributor.department | COMMUNITY,OCCUPATIONAL & FAMILY MEDICINE | |
dc.contributor.department | CHEMISTRY | |
dc.description.doi | 10.1016/0378-4347(94)00458-H | |
dc.description.sourcetitle | Journal of Chromatography B: Biomedical Applications | |
dc.description.volume | 663 | |
dc.description.issue | 2 | |
dc.description.page | 247-253 | |
dc.description.coden | JCBBE | |
dc.identifier.isiut | A1995QE30200008 | |
Appears in Collections: | Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.