Please use this identifier to cite or link to this item: https://doi.org/10.11607/jomi.6855
DC FieldValue
dc.titleComparison of Three-Dimensional Accuracy of Digital and Conventional Implant Impressions: Effect of Interimplant Distance in an Edentulous Arch
dc.contributor.authorTan, Ming Yi
dc.contributor.authorYee, Sophia Hui Xin
dc.contributor.authorWong, Keng Mun
dc.contributor.authorTan, Ying Han
dc.contributor.authorTan, Keson Beng Choon
dc.date.accessioned2024-01-25T02:20:31Z
dc.date.available2024-01-25T02:20:31Z
dc.date.issued2019-01-01
dc.identifier.citationTan, Ming Yi, Yee, Sophia Hui Xin, Wong, Keng Mun, Tan, Ying Han, Tan, Keson Beng Choon (2019-01-01). Comparison of Three-Dimensional Accuracy of Digital and Conventional Implant Impressions: Effect of Interimplant Distance in an Edentulous Arch. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS 34 (2) : 366-380. ScholarBank@NUS Repository. https://doi.org/10.11607/jomi.6855
dc.identifier.issn0882-2786
dc.identifier.issn1942-4434
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/246845
dc.description.abstractPurpose: This study compared the three-dimensional (3D) accuracy of conventional impressions with digital impression systems (intraoral scanners and dental laboratory scanners) for two different interimplant distances in maxillary edentulous arches. Materials and Methods: Six impression systems comprising one conventional impression material (Impregum), two intraoral scanners (TRIOS and True Definition), and three dental laboratory scanners (Ceramill Map400, inEos X5, and D900) were evaluated on two completely edentulous maxillary arch master models (A and B) with six and eight implants, respectively. Centroid positions at the implant platform level were derived using either physical or virtual probe hits with a coordinate measuring machine. Comparison of centroid positions between master and test models (n = 5) defined linear distortions (d x , d y , d z ), global linear distortions (d R ), and 3D reference distance distortions between implants (ΔR). The two-dimensional (2D) angles between the central axis of each implant to the x- or y-axes were compared to derive absolute angular distortions (Absdθ x , Absdθ y ). Results: Model A mean d R ranged from 8.7 ± 8.3 μm to 731.7 ± 62.3 μm. Model B mean d R ranged from 16.3 ± 9 μm to 620.2 ± 63.2 μm. Model A mean Absdθ x ranged from 0.021 ± 0.205 degrees to -2.349 ± 0.166 degrees, and mean Absdθ y ranged from -0.002 ± 0.160 degrees to -0.932 ± 0.290 degrees. Model B mean Absdθ x ranged from -0.007 ± 0.076 degrees to -0.688 ± 0.574 degrees, and mean Absdθ y ranged from -0.018 ± 0.048 degrees to -1.052 ± 0.297 degrees. One-way analysis of variance (ANOVA) by impression system revealed significant differences among test groups for d R and ΔR in both models, with True Definition exhibiting the poorest accuracy. Independent samples t tests for d R , between homologous implant location pairs in model A vs B, revealed the presence of two to four significant pairings (out of seven possible) for the intraoral scanner systems, in which instances d R was larger in model A by 110 to 150 μm. Conclusion: Reducing interimplant distance may decrease global linear distortions for intraoral scanner systems, but had no effect on Impregum and the dental laboratory scanner systems. Impregum consistently exhibited the best or second-best accuracy at all implant locations, while True Definition exhibited the poorest accuracy for all linear distortions in both models A and B. Impression systems could not be consistently ranked for absolute angular distortions.
dc.language.isoen
dc.publisherQUINTESSENCE PUBLISHING CO INC
dc.sourceElements
dc.subjectScience & Technology
dc.subjectLife Sciences & Biomedicine
dc.subjectDentistry, Oral Surgery & Medicine
dc.subject3D accuracy
dc.subjectCMM
dc.subjectdental laboratory scanner
dc.subjectdigital impression
dc.subjectimplant
dc.subjectintraoral scanner
dc.subjectTOLERANCE MEASUREMENTS
dc.subjectIN-VITRO
dc.subjectFIT
dc.typeArticle
dc.date.updated2024-01-24T08:46:35Z
dc.contributor.departmentDENTISTRY
dc.description.doi10.11607/jomi.6855
dc.description.sourcetitleINTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
dc.description.volume34
dc.description.issue2
dc.description.page366-380
dc.published.stateUnpublished
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Comparison of Three-Dimensional Accuracy of Digital and Conventional Implant Impressions- Effect of Interimplant Distance in an Edentulous Arch.docx2.96 MBMicrosoft Word XML

OPEN

Pre-printView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.