Please use this identifier to cite or link to this item: https://doi.org/10.1186/s12882-023-03360-6
DC FieldValue
dc.titleSegmental bioimpedance in pregnant end stage renal failure patient for dry weight titration and volume management (case report).
dc.contributor.authorHaroon, Sabrina
dc.contributor.authorTan, Jia Neng
dc.contributor.authorLau, Titus
dc.contributor.authorChan, Shiao-Yng
dc.contributor.authorDavenport, Andrew
dc.date.accessioned2023-11-01T02:56:55Z
dc.date.available2023-11-01T02:56:55Z
dc.date.issued2023-10-24
dc.identifier.citationHaroon, Sabrina, Tan, Jia Neng, Lau, Titus, Chan, Shiao-Yng, Davenport, Andrew (2023-10-24). Segmental bioimpedance in pregnant end stage renal failure patient for dry weight titration and volume management (case report).. BMC Nephrol 24 (1) : 308-. ScholarBank@NUS Repository. https://doi.org/10.1186/s12882-023-03360-6
dc.identifier.issn1471-2369
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/245685
dc.description.abstractBACKGROUND: Volume assessment, dry weight titration, and blood pressure control in pregnant kidney failure patients are often challenging, with physiological fluid accumulation in the trunk and lower limbs and an increased risk of preeclampsia. We used segmental bioimpedance in the volume management of our kidney failure patient on haemodialysis. CASE PRESENTATION: We report a case of a female patient on maintenance haemodiafiltration with no residual kidney function for whom we used segmental bioimpedance to guide dry weight adjustment. At different gestational periods, we targeted a different extracellular to total body water ratio according to body segments. This allowed us to support her high-risk pregnancy, identify her as probably developing preeclampsia and trigger a plan for closer monitoring and delivery during the third trimester when she had rapid weight gain. CONCLUSION: Segmental bioimpedance is a practical, simple, and non-invasive test that can be performed at the dialysis unit and is useful as an adjunct decision-making tool in the management of pregnant dialysis patients.
dc.sourceElements
dc.subjectHaemodialysis
dc.subjectPregnancy
dc.subjectSegmental bioimpedance
dc.subjectHumans
dc.subjectFemale
dc.subjectPregnancy
dc.subjectRenal Dialysis
dc.subjectPre-Eclampsia
dc.subjectKidney Failure, Chronic
dc.subjectBlood Pressure
dc.subjectRenal Insufficiency
dc.subjectBody Weight
dc.subjectElectric Impedance
dc.typeArticle
dc.date.updated2023-11-01T01:34:00Z
dc.contributor.departmentMEDICINE
dc.contributor.departmentOBSTETRICS & GYNAECOLOGY
dc.description.doi10.1186/s12882-023-03360-6
dc.description.sourcetitleBMC Nephrol
dc.description.volume24
dc.description.issue1
dc.description.page308-
dc.published.stateUnpublished
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Segmental bioimpedance in pregnant end stage renal failure patient for dry weight titration and volume management (case repo.pdf910.39 kBAdobe PDF

OPEN

PublishedView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.