Please use this identifier to cite or link to this item: https://doi.org/10.5999/aps.2021.01123
DC FieldValue
dc.titleThe superior lateral genicular artery flap for reconstruction of knee and proximal leg defects
dc.contributor.authorLow, OW
dc.contributor.authorLoh, TF
dc.contributor.authorLee, H
dc.contributor.authorYap, YL
dc.contributor.authorLim, J
dc.contributor.authorLim, TC
dc.contributor.authorNallathamby, V
dc.date.accessioned2022-12-05T06:41:11Z
dc.date.available2022-12-05T06:41:11Z
dc.date.issued2022-01-01
dc.identifier.citationLow, OW, Loh, TF, Lee, H, Yap, YL, Lim, J, Lim, TC, Nallathamby, V (2022-01-01). The superior lateral genicular artery flap for reconstruction of knee and proximal leg defects. Archives of Plastic Surgery 49 (1) : 108-114. ScholarBank@NUS Repository. https://doi.org/10.5999/aps.2021.01123
dc.identifier.issn22346163
dc.identifier.issn22346171
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/235341
dc.description.abstractReconstruction of defects around the knee region requires thin and pliable skin. The superior lateral genicular artery (SLGA) flap provides an excellent alternative to muscle-based flaps. The anatomy and the surgical techniques of the SLGA flap were reviewed and the results of cases using the SLGA flap for coverage of knee and proximal leg defects were analyzed. SLGA flaps were performed in two cases and followed up for at least 6 months. Twelve articles on the use of the SLGA flap were also identified. A review of 39 cases showed that the mean diameter of the perforator supplying the skin of the flap was 1.04 mm, while the mean diameter of the SLGA at its origin was 1.78 mm. The mean length of the pedicle measured from the origin of the popliteal artery was 7.44 cm. The average dimensions of the flap were 14.8×6.6 cm with primary closure of the donor site in 61.5% of cases. Of these cases, 38.5% were due to trauma, 23.1% were post-burn complications, 12.8% were defects after resection of tumors, and 10.3% were for ulcers post-bursectomy. The most common complication was flap tip necrosis. All studies reported favorable outcomes with complete wound healing.
dc.publisherGeorg Thieme Verlag KG
dc.sourceElements
dc.subjectFlap
dc.subjectKnee
dc.subjectLower limb
dc.subjectPerforator flap
dc.subjectReconstruction
dc.typeArticle
dc.date.updated2022-12-05T06:36:16Z
dc.contributor.departmentOPHTHALMOLOGY
dc.contributor.departmentSURGERY
dc.description.doi10.5999/aps.2021.01123
dc.description.sourcetitleArchives of Plastic Surgery
dc.description.volume49
dc.description.issue1
dc.description.page108-114
dc.published.statePublished
Appears in Collections:Elements
Staff Publications

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
The superior lateral genicular artery flap for reconstruction of knee and proximal leg defects.pdf1.49 MBAdobe PDF

OPEN

PublishedView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.