Please use this identifier to cite or link to this item:
https://doi.org/10.1016/j.sdentj.2021.01.003
DC Field | Value | |
---|---|---|
dc.title | Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites | |
dc.contributor.author | Diab, Rana Abdelbaset | |
dc.contributor.author | Yap, Adrian Ujin | |
dc.contributor.author | Gonzalez, Maria Angela Garcia | |
dc.contributor.author | Yahya, Noor Azlin | |
dc.date.accessioned | 2022-10-13T01:09:39Z | |
dc.date.available | 2022-10-13T01:09:39Z | |
dc.date.issued | 2021-01-01 | |
dc.identifier.citation | Diab, Rana Abdelbaset, Yap, Adrian Ujin, Gonzalez, Maria Angela Garcia, Yahya, Noor Azlin (2021-01-01). Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites. Saudi Dental Journal 33 (8) : 1184-1189. ScholarBank@NUS Repository. https://doi.org/10.1016/j.sdentj.2021.01.003 | |
dc.identifier.issn | 1013-9052 | |
dc.identifier.uri | https://scholarbank.nus.edu.sg/handle/10635/232767 | |
dc.description.abstract | Objective: To investigate the effect of light-curing distance on the effectiveness of cure (EC) of bulk-fill resin-based composites (RBCs). Materials and methods: Two bulk-fill RBCs (a Tetric N-Ceram Bulk Fill (TN) and a Filtek Bulk Fill (FK)) are evaluated. Specimens (4 mm high) are cured for 20 s at different distances (0 mm (D0), 2 mm (D2), 4 mm (D4), 6 mm (D6) and 8 mm (D8)) and stored for 24 h in 100% relative humidity at 37 °C. The top and bottom surface hardness (SH) (n = 12) are assessed using a Knoop microhardness tester and the EC is calculated. The EC is characterized by the hardness ratio (HR) (mean bottom: top SH). An HR of 0.8 is used as the benchmark for an effective/adequate cure. Data are analyzed using one-way analysis of variance and Tukey's post hoc test (? = 0.05). Correlations between the top and bottom surfaces are examined using the Pearson correlation (? = 0.05). Results: For the TN, the HR at D8 is significantly lower than all other light-curing distances, while for the FK, it is significantly lower than D0 only. Conclusion: The effect of light-curing distance on the EC of bulk-fill RBCs is material dependent. Notwithstanding the light-curing distance, the EC of the FK and TN is below the threshold HR value of 0.8 when photopolymerized for 20 s in 4 mm increments in black opaque molds. © 2021 King Saud University | |
dc.publisher | Elsevier B.V. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.source | Scopus OA2021 | |
dc.subject | Composite resins | |
dc.subject | Curing light | |
dc.subject | Hardness | |
dc.type | Article | |
dc.contributor.department | DENTISTRY | |
dc.description.doi | 10.1016/j.sdentj.2021.01.003 | |
dc.description.sourcetitle | Saudi Dental Journal | |
dc.description.volume | 33 | |
dc.description.issue | 8 | |
dc.description.page | 1184-1189 | |
Appears in Collections: | Elements Staff Publications |
Show simple item record
Files in This Item:
File | Description | Size | Format | Access Settings | Version | |
---|---|---|---|---|---|---|
10_1016_j_sdentj_2021_01_003.pdf | 688.7 kB | Adobe PDF | OPEN | None | View/Download |
This item is licensed under a Creative Commons License