Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.sdentj.2021.01.003
DC FieldValue
dc.titleImpact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
dc.contributor.authorDiab, Rana Abdelbaset
dc.contributor.authorYap, Adrian Ujin
dc.contributor.authorGonzalez, Maria Angela Garcia
dc.contributor.authorYahya, Noor Azlin
dc.date.accessioned2022-10-13T01:09:39Z
dc.date.available2022-10-13T01:09:39Z
dc.date.issued2021-01-01
dc.identifier.citationDiab, Rana Abdelbaset, Yap, Adrian Ujin, Gonzalez, Maria Angela Garcia, Yahya, Noor Azlin (2021-01-01). Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites. Saudi Dental Journal 33 (8) : 1184-1189. ScholarBank@NUS Repository. https://doi.org/10.1016/j.sdentj.2021.01.003
dc.identifier.issn1013-9052
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/232767
dc.description.abstractObjective: To investigate the effect of light-curing distance on the effectiveness of cure (EC) of bulk-fill resin-based composites (RBCs). Materials and methods: Two bulk-fill RBCs (a Tetric N-Ceram Bulk Fill (TN) and a Filtek Bulk Fill (FK)) are evaluated. Specimens (4 mm high) are cured for 20 s at different distances (0 mm (D0), 2 mm (D2), 4 mm (D4), 6 mm (D6) and 8 mm (D8)) and stored for 24 h in 100% relative humidity at 37 °C. The top and bottom surface hardness (SH) (n = 12) are assessed using a Knoop microhardness tester and the EC is calculated. The EC is characterized by the hardness ratio (HR) (mean bottom: top SH). An HR of 0.8 is used as the benchmark for an effective/adequate cure. Data are analyzed using one-way analysis of variance and Tukey's post hoc test (? = 0.05). Correlations between the top and bottom surfaces are examined using the Pearson correlation (? = 0.05). Results: For the TN, the HR at D8 is significantly lower than all other light-curing distances, while for the FK, it is significantly lower than D0 only. Conclusion: The effect of light-curing distance on the EC of bulk-fill RBCs is material dependent. Notwithstanding the light-curing distance, the EC of the FK and TN is below the threshold HR value of 0.8 when photopolymerized for 20 s in 4 mm increments in black opaque molds. © 2021 King Saud University
dc.publisherElsevier B.V.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceScopus OA2021
dc.subjectComposite resins
dc.subjectCuring light
dc.subjectHardness
dc.typeArticle
dc.contributor.departmentDENTISTRY
dc.description.doi10.1016/j.sdentj.2021.01.003
dc.description.sourcetitleSaudi Dental Journal
dc.description.volume33
dc.description.issue8
dc.description.page1184-1189
Appears in Collections:Elements