Please use this identifier to cite or link to this item: https://doi.org/10.3390/fluids6060220
DC FieldValue
dc.titleLow pressure experimental validation of low-dimensional analytical model for air–water two-phase transient flow in horizontal pipelines
dc.contributor.authorMnasri, Hamdi
dc.contributor.authorMeziou, Amine
dc.contributor.authorFranchek, Matthew A.
dc.contributor.authorLoh, Wai Lam
dc.contributor.authorWan, Thiam Teik
dc.contributor.authorTam, Nguyen Dinh
dc.contributor.authorWassar, Taoufik
dc.contributor.authorTang, Yingjie
dc.contributor.authorGrigoriadis, Karolos
dc.date.accessioned2022-10-12T08:05:28Z
dc.date.available2022-10-12T08:05:28Z
dc.date.issued2021-06-11
dc.identifier.citationMnasri, Hamdi, Meziou, Amine, Franchek, Matthew A., Loh, Wai Lam, Wan, Thiam Teik, Tam, Nguyen Dinh, Wassar, Taoufik, Tang, Yingjie, Grigoriadis, Karolos (2021-06-11). Low pressure experimental validation of low-dimensional analytical model for air–water two-phase transient flow in horizontal pipelines. Fluids 6 (6) : 220. ScholarBank@NUS Repository. https://doi.org/10.3390/fluids6060220
dc.identifier.issn2311-5521
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/232452
dc.description.abstractThis paper presents a low-pressure experimental validation of a two-phase transient pipeline flow model. Measured pressure and flow rate data are collected for slug and froth flow patterns at the low pressure of 6 bar at the National University of Singapore Multiphase Flow Loop facility. The analyzed low-dimensional model proposed in comprises a steady-state multiphase flow model in series with a linear dynamic model capturing the flow transients. The model is based on a dissipative distributed parameter model for transient flow in transmission lines employing equivalent fluid properties. These parameters are based solely on the flowing conditions, fluid properties and pipeline geometry. OLGA simulations are employed as an independent method to validate the low-dimension model. Both low-dimensional and OLGA models are evaluated based on the estimated two-phase pressure transients for varying gas volume fraction (GVF). Both models estimated the two-phase flow transient pressure within 5% mean absolute percent error of the laboratory data. Additionally, an unavoidable presence of entrained air within a pipeline is confirmed for the case of 0% GVF as evidenced by the pressure transient estimation. Thus, dampened oscillations in the simulated 0% GVF case exists owing to an increase in the fluid compressibility. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
dc.publisherMDPI AG
dc.rightsAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceScopus OA2021
dc.subjectExperimental validation
dc.subjectMultiphase flow
dc.subjectOLGA
dc.subjectReduced-order modeling
dc.typeArticle
dc.contributor.departmentCOLLEGE OF DESIGN AND ENGINEERING
dc.contributor.departmentCIVIL AND ENVIRONMENTAL ENGINEERING
dc.contributor.departmentMECHANICAL ENGINEERING
dc.description.doi10.3390/fluids6060220
dc.description.sourcetitleFluids
dc.description.volume6
dc.description.issue6
dc.description.page220
Appears in Collections:Elements
Staff Publications

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_3390_fluids6060220.pdf9.97 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons