dc.titleCompensating uncertainties in force sensing for robotic-assisted palpation
dc.contributor.authorGuo, J.
dc.contributor.authorXiao, B.
dc.contributor.authorRen, H.
dc.date.accessioned2021-12-06T04:24:17Z
dc.date.available2021-12-06T04:24:17Z
dc.date.issued2019
dc.identifier.citationGuo, J., Xiao, B., Ren, H. (2019). Compensating uncertainties in force sensing for robotic-assisted palpation. Applied Sciences (Switzerland) 9 (12) : 573. ScholarBank@NUS Repository. https://doi.org/10.3390/app9122573
dc.identifier.issn2076-3417
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/209570
dc.description.abstractForce sensing in robotic-assisted minimally invasive surgery (RMIS) is crucial for performing dedicated surgical procedures, such as bilateral teleoperation and palpation. Due to the bio-compatibility and sterilization requirements, a specially designed surgical tool/shaft is normally attached to the sensor while contacting the organ targets. Through this design, the measured force from the sensor usually contains uncertainties, such as noise, inertial force etc., and thus cannot reflect the actual interaction force with the tissue environment. Motivated to provide the authentic contact force between a robotic tool and soft tissue, we proposed a data-driven force compensation scheme without intricate modeling to reduce the effects of force measurement uncertainties. In this paper, a neural-network-based approach is utilized to automatically model the inertial force subject to noise during the robotic palpation procedure, then the exact contact force can be obtained through the force compensation method which cancels the noise and inertial force. Following this approach, the genuine interaction force during the palpation task can be achieved furthermore to improve the appraisal of the tumor surrounded by the soft tissue. Experiments are conducted with robotic-assisted palpation tasks on a silicone-based soft tissue phantom and the results verify the effectiveness of the suggested method. © 2019 by the authors.
dc.publisherMDPI AG
dc.rightsAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceScopus OA2019
dc.subjectRobotic-assisted palpation
dc.subjectSensor uncertainties
dc.subjectTumor location
dc.typeArticle
dc.contributor.departmentBIOMEDICAL ENGINEERING
dc.description.doi10.3390/app9122573
dc.description.sourcetitleApplied Sciences (Switzerland)
dc.description.volume9
dc.description.issue12
dc.description.page573
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_3390_app9122573.pdf1.73 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons