Please use this identifier to cite or link to this item: https://doi.org/10.2147/OTT.S106758
DC FieldValue
dc.titleAccelerated partial breast irradiation in an Asian population: dosimetric findings and preliminary results of a multicatheter interstitial program
dc.contributor.authorKoh, Yaling Vicky
dc.contributor.authorTan, Poh Wee
dc.contributor.authorBuhari, Shaik Ahmad
dc.contributor.authorIau, Philip
dc.contributor.authorChan, Ching Wan
dc.contributor.authorShen, Liang
dc.contributor.authorTan, Sing Huang
dc.contributor.authorTang, Johann I-Hsiung
dc.date.accessioned2021-11-23T05:55:23Z
dc.date.available2021-11-23T05:55:23Z
dc.date.issued2016-01-01
dc.identifier.citationKoh, Yaling Vicky, Tan, Poh Wee, Buhari, Shaik Ahmad, Iau, Philip, Chan, Ching Wan, Shen, Liang, Tan, Sing Huang, Tang, Johann I-Hsiung (2016-01-01). Accelerated partial breast irradiation in an Asian population: dosimetric findings and preliminary results of a multicatheter interstitial program. ONCOTARGETS AND THERAPY 9 : 5561-5566. ScholarBank@NUS Repository. https://doi.org/10.2147/OTT.S106758
dc.identifier.issn11786930
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/207384
dc.description.abstractIntroduction: Accelerated partial breast irradiation (APBI) using the multicatheter method has excellent cosmesis and low rates of long-term toxicity. However, there are few studies looking at the feasibility of this procedure and the outcomes in an Asian population. This study aims to look at outcomes at our hospital. Methods: We identified 121 patients treated with APBI at our center between 2008 and 2014. The median follow-up for our patient group was 30 months (range 3.7-66.5). The prescribed dose per fraction was 3.4 Gy in 10 fractions. In this study population, 71% of the patients were Chinese while 15% (n=19) were of other Asian ethnicity. Results: In this study, the median breast volume was 850 cc (range 216-2,108) with 59.5% (n=72) patients with a breast volume of,1,000 cc. The average planning target volume was 134 cc (range 28-324). The number of catheters used ranged from 8 to 25 with an average of 18 catheters used per patient. We achieved an average dose homogeneity index of 0.76 in our patients. The average D90(%) was 105% and the average D90(Gy) was 3.6 Gy per fraction. The median volume receiving 100% of the prescribed dose (V100) was 161.7 cc (range 33.9-330.1), 150% of the prescribed dose (V150) and 200% of the prescribed dose (V200) was 39.4 cc (range 14.6-69.6) and 14.72 cc (range 6.48-22.25), respectively. Our dosimetric outcomes were excellent even in patients with breast volume under 1,000 cc. There were no cases of grade 3 skin toxicity or acute pneumonitis. Two patients had a postoperative infection and two patients had fat necrosis postprocedure. Conclusion: Multicatheter high dose rate APBI is a safe and feasible procedure that can be carried out with minimal toxicity in Asian patients with breast volumes under 1,000 cc.
dc.language.isoen
dc.publisherDOVE MEDICAL PRESS LTD
dc.sourceElements
dc.subjectScience & Technology
dc.subjectLife Sciences & Biomedicine
dc.subjectBiotechnology & Applied Microbiology
dc.subjectOncology
dc.subjectbreast
dc.subjectAsian
dc.subjectmulticatheter
dc.subjectbrachytherapy
dc.subject20-YEAR FOLLOW-UP
dc.subjectCONSERVING SURGERY
dc.subjectRANDOMIZED-TRIAL
dc.subjectBRACHYTHERAPY
dc.subjectCANCER
dc.subjectFEASIBILITY
dc.subjectMASTECTOMY
dc.subjectLUMPECTOMY
dc.subjectEXPERIENCE
dc.subjectOUTCOMES
dc.typeArticle
dc.date.updated2021-11-18T02:48:59Z
dc.contributor.departmentMEDICINE
dc.contributor.departmentSURGERY
dc.description.doi10.2147/OTT.S106758
dc.description.sourcetitleONCOTARGETS AND THERAPY
dc.description.volume9
dc.description.page5561-5566
dc.published.statePublished
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Accelerated partial breast irradiation in an Asian population dosimetric findings and preliminary results of a multicatheter.pdf531.31 kBAdobe PDF

OPEN

PublishedView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.