Please use this identifier to cite or link to this item: https://doi.org/10.3390/molecules25204835
DC FieldValue
dc.titleAffinity of antifungal isoxazolo[3,4?b]pyridine?3(1H)?ones to phospholipids in immobilized artificial membrane (IAM) chromatography
dc.contributor.authorCiura, K.
dc.contributor.authorFedorowicz, J.
dc.contributor.authorŽuvela, P.
dc.contributor.authorLovri?, M.
dc.contributor.authorKapica, H.
dc.contributor.authorBaranowski, P.
dc.contributor.authorSawicki, W.
dc.contributor.authorWong, M.W.
dc.contributor.authorS?czewski, J.
dc.date.accessioned2021-08-18T02:49:35Z
dc.date.available2021-08-18T02:49:35Z
dc.date.issued2020
dc.identifier.citationCiura, K., Fedorowicz, J., Žuvela, P., Lovri?, M., Kapica, H., Baranowski, P., Sawicki, W., Wong, M.W., S?czewski, J. (2020). Affinity of antifungal isoxazolo[3,4?b]pyridine?3(1H)?ones to phospholipids in immobilized artificial membrane (IAM) chromatography. Molecules 25 (20) : 4835. ScholarBank@NUS Repository. https://doi.org/10.3390/molecules25204835
dc.identifier.issn14203049
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/197444
dc.description.abstractCurrently, rapid evaluation of the physicochemical parameters of drug candidates, such as lipophilicity, is in high demand owing to it enabling the approximation of the processes of absorption, distribution, metabolism, and elimination. Although the lipophilicity of drug candidates is determined using the shake flash method (n?octanol/water system) or reversed phase liquid chromatography (RP?LC), more biosimilar alternatives to classical lipophilicity measurement are currently available. One of the alternatives is immobilized artificial membrane (IAM) chromatography. The present study is a continuation of our research focused on physiochemical characterization of biologically active derivatives of isoxazolo[3,4?b]pyridine?3(1H)?ones. The main goal of this study was to assess the affinity of isoxazolones to phospholipids using IAM chromatography and compare it with the lipophilicity parameters established by reversed phase chromatography. Quantitative structure–retention relationship (QSRR) modeling of IAM retention using differential evolution coupled with partial least squares (DE?PLS) regression was performed. The results indicate that in the studied group of structurally related isoxazolone derivatives, discrepancies occur between the retention under IAM and RP?LC conditions. Although some correlation between these two chromatographic methods can be found, lipophilicity does not fully explain the affinities of the investigated molecules to phospholipids. QSRR analysis also shows common factors that contribute to retention under IAM and RP?LC conditions. In this context, the significant influences of WHIM and GETAWAY descriptors in all the obtained models should be highlighted. © 2020 by the authors. Licensee MDPI, Basel, Switzerland.
dc.publisherMDPI AG
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceScopus OA2020
dc.subjectIAM?HPLC
dc.subjectImmobilized artificial membrane
dc.subjectIsoxazolone
dc.subjectIsoxazolo[3,4?b]pyridin?3(1H)?one
dc.typeArticle
dc.contributor.departmentCHEMISTRY
dc.description.doi10.3390/molecules25204835
dc.description.sourcetitleMolecules
dc.description.volume25
dc.description.issue20
dc.description.page4835
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_3390_molecules25204835.pdf1.32 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons