dc.titleQA/QC plan and evaluation of field strength and permeability value for deep cement mixing
dc.contributor.authorChew, SH
dc.contributor.authorYim, HMA
dc.contributor.authorKoh, JW
dc.contributor.authorChua, KE
dc.contributor.authorGng, ZX
dc.date.accessioned2021-06-07T02:11:28Z
dc.date.available2021-06-07T02:11:28Z
dc.date.issued2020-01-01
dc.identifier.citationChew, SH, Yim, HMA, Koh, JW, Chua, KE, Gng, ZX (2020-01-01). QA/QC plan and evaluation of field strength and permeability value for deep cement mixing. International Journal of GEOMATE 19 (74) : 52-58. ScholarBank@NUS Repository. https://doi.org/10.21660/2020.74.9450
dc.identifier.issn21862982
dc.identifier.issn21862990
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/191821
dc.description.abstractDeep Cement Mixing (DCM) is widely used to improve the strength and stiffness of soil by mixing it with cement. When DCM is used as a low permeability barrier for water cut off, permeability must be tested in addition to the usual strength values. One concern in DCM construction is the quality assurance and quality control (QA/QC) of this technique to ensure uniformity along the DCM column. It is even more crucial when low permeability is required for the DCM column to be used as a seepage cut-off in an earth bund, in addition to its strength requirement. In this application, the DCM columns require low permeability and adequate strength. In this paper, two QA/QC aspects will be evaluated: the operational control and the evaluation of the treated DCM column. The operational control in terms of mixing time, cement content, rotation speed and mixing energy will be studied to gain an understanding of how strength and permeability changes with the variability of the soil with depth. A rational QA/QC plan will be briefly proposed to ensure a consistent and rational method is developed for the evaluation of the strength and permeability variation of the treated soils over the area and the depth. These will help in the development of acceptable characteristic value for the geotechnical parameters of soils treated with DCM (in line with Eurocode 7).
dc.publisherInternational Journal of Geomate
dc.sourceElements
dc.subjectDeep cement mixing
dc.subjectEurocode 7
dc.subjectPermeability
dc.subjectQuality
dc.subjectSoil improvement
dc.typeArticle
dc.date.updated2021-06-07T01:07:57Z
dc.contributor.departmentCIVIL AND ENVIRONMENTAL ENGINEERING
dc.description.doi10.21660/2020.74.9450
dc.description.sourcetitleInternational Journal of GEOMATE
dc.description.volume19
dc.description.issue74
dc.description.page52-58
dc.published.statePublished
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
QAQC PLAN AND EVALUATION OF FIELD STRENGTH AND PERMEABILITY VALUE FOR DEEP CEMENT MIXING.pdfAccepted version828.72 kBAdobe PDF

OPEN

PublishedView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.