Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.apenergy.2021.116533
DC FieldValue
dc.titleGlobal sensitivity and uncertainty analysis of the levelised cost of storage (LCOS) for solar-PV-powered cooling
dc.contributor.authorLuerssen, Christoph
dc.contributor.authorVerbois, Hadrien
dc.contributor.authorGandhi, Oktoviano
dc.contributor.authorTHOMAS GUENTER REINDL
dc.contributor.authorSEKHAR,SITARAMAN CHANDRA
dc.contributor.authorCHEONG KOK WAI,DAVID
dc.date.accessioned2021-03-30T08:19:52Z
dc.date.available2021-03-30T08:19:52Z
dc.date.issued2021-03-15
dc.identifier.citationLuerssen, Christoph, Verbois, Hadrien, Gandhi, Oktoviano, THOMAS GUENTER REINDL, SEKHAR,SITARAMAN CHANDRA, CHEONG KOK WAI,DAVID (2021-03-15). Global sensitivity and uncertainty analysis of the levelised cost of storage (LCOS) for solar-PV-powered cooling. APPLIED ENERGY 286. ScholarBank@NUS Repository. https://doi.org/10.1016/j.apenergy.2021.116533
dc.identifier.issn0306-2619
dc.identifier.issn1872-9118
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/187920
dc.description.abstractIn this paper, we investigate the sensitivity of the parameters affecting the levelised cost of storage (LCOS) of Lithium ion (Li-Ion) battery storage and chilled water storage for on-grid PV-powered cooling applications, namely an office and a hotel building. Therefore, we carry out multi-objective optimisations to minimise the LCOS and maximise the self-sufficiency based on TRNSYS simulation models. For selected optimal solutions, we perform Morris and Sobol global sensitivity as well as uncertainty analyses. The results show that the chilled water storage yields up to 8 ctUSD/kWhel lower LCOS than the battery storage at the same self-sufficiency; however, the battery storage can increase the self-sufficiency more. The dominant parameter affecting the LCOS is the storage lifetime for the battery. Careful design of the dedicated chiller plant to charge the storage is important for the system configuration with chilled water storage. Because of the wide range of possible battery lifetimes, the 90% confidence interval for the LCOS of battery storage is 2.6 times larger than the one for chilled water storage given the input parameter ranges in this study. The future trend indicates that battery storage is expected to become more competitive due to technological advancements and favourable price developments.
dc.language.isoen
dc.publisherELSEVIER SCI LTD
dc.sourceElements
dc.subjectScience & Technology
dc.subjectTechnology
dc.subjectEnergy & Fuels
dc.subjectEngineering, Chemical
dc.subjectEngineering
dc.subjectBattery
dc.subjectEnergy storage
dc.subjectLCOS
dc.subjectPV-powered cooling
dc.subjectThermal energy storage
dc.subjectSensitivity analysis
dc.typeArticle
dc.date.updated2021-03-30T06:26:44Z
dc.contributor.departmentBUILDING
dc.contributor.departmentSOLAR ENERGY RESEARCH INST OF S'PORE
dc.description.doi10.1016/j.apenergy.2021.116533
dc.description.sourcetitleAPPLIED ENERGY
dc.description.volume286
dc.published.statePublished
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
Global-sensitivity-and-uncertainty-final-accepted-manuscript-Christoph.pdfAccepted version724.58 kBAdobe PDF

OPEN

Post-printView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.