Please use this identifier to cite or link to this item: https://doi.org/10.1155/2017/6906139
DC FieldValue
dc.titleA Rabbit Model Study to Determine the Efficacy of a Prototype Corneal Endothelium Protector during Cataract Surgery
dc.contributor.authorChew, A.C.Y
dc.contributor.authorChan, A
dc.contributor.authorNongpiur, M.E
dc.contributor.authorPeh, G
dc.contributor.authorBarathi, V.A
dc.contributor.authorLwin, N.C
dc.contributor.authorOng, C
dc.contributor.authorPerera, S
dc.date.accessioned2020-11-17T06:39:44Z
dc.date.available2020-11-17T06:39:44Z
dc.date.issued2017
dc.identifier.citationChew, A.C.Y, Chan, A, Nongpiur, M.E, Peh, G, Barathi, V.A, Lwin, N.C, Ong, C, Perera, S (2017). A Rabbit Model Study to Determine the Efficacy of a Prototype Corneal Endothelium Protector during Cataract Surgery. Journal of Ophthalmology 2017 : 6906139. ScholarBank@NUS Repository. https://doi.org/10.1155/2017/6906139
dc.identifier.issn2090-004X
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/183570
dc.description.abstractPurpose. We evaluated the efficacy and safety of a mechanical device, the P-chute, in corneal endothelium preservation during phacoemulsification in a rabbit model. Methods. Twenty-four rabbits were randomly assigned into 2 groups. One eye of each rabbit underwent phacoemulsification that simulated the removal of a dense nucleus, with or without the P-chute. Serial slit-lamp examinations, anterior segment optical coherence tomography (ASOCT) scans, and specular microscopy were performed. Three rabbits from each group were sacrificed on postoperative days (PODs) 1, 5, 7, and 14. Histological analysis of the corneas was performed. Results. There was a trend towards lesser endothelial cell loss for the P-chute group at POD1 (4.9% versus 12.5%, p=0.53), POD5 (10.4% versus 12.2%, p=0.77), and POD7 (10.5% versus 17.2%, p=0.52). There was no significant difference in the corneal thickness (p=>0.05) between the 2 groups. The insertion of the device was challenging. The use of the P-chute only added an extra 15% to the surgical time. Conclusions. There was a trend towards better endothelium preservation with the P-chute even though the results were not statistically significant. We believe that the device could be useful in certain surgical situations. Further work is needed to improve the device insertion. © 2017 Annabel C. Y. Chew et al.
dc.publisherHindawi
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceUnpaywall 20201031
dc.typeArticle
dc.contributor.departmentOPHTHALMOLOGY
dc.contributor.departmentDUKE-NUS MEDICAL SCHOOL
dc.description.doi10.1155/2017/6906139
dc.description.sourcetitleJournal of Ophthalmology
dc.description.volume2017
dc.description.page6906139
dc.published.statePublished
Appears in Collections:Elements
Staff Publications

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_1155_2017_6906139.pdf3.3 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons