Please use this identifier to cite or link to this item: https://doi.org/10.1007/s40565-015-0179-y
DC FieldValue
dc.titleOptimal electromagnetic hybrid negative current compensation method for high-speed railway power supply system
dc.contributor.authorYuan, J
dc.contributor.authorZhong, Y
dc.contributor.authorZhang, C
dc.contributor.authorZeng, W
dc.contributor.authorChen, B
dc.contributor.authorTian, C
dc.contributor.authorDeng, C
dc.contributor.authorZhou, M
dc.contributor.authorMuramatsu, K
dc.contributor.authorWang, J
dc.date.accessioned2020-11-10T08:02:36Z
dc.date.available2020-11-10T08:02:36Z
dc.date.issued2016
dc.identifier.citationYuan, J, Zhong, Y, Zhang, C, Zeng, W, Chen, B, Tian, C, Deng, C, Zhou, M, Muramatsu, K, Wang, J (2016). Optimal electromagnetic hybrid negative current compensation method for high-speed railway power supply system. Journal of Modern Power Systems and Clean Energy 4 (1) : 123-134. ScholarBank@NUS Repository. https://doi.org/10.1007/s40565-015-0179-y
dc.identifier.issn21965625
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/183353
dc.description.abstractTo achieve economical compensation for the huge-capacity negative sequence currents generated by high-speed railway load, an electromagnetic hybrid compensation system (EHCS) and control strategy is proposed. The EHCS is made up of a small-capacity railway static power conditioner (RPC) and a large-capacity magnetic static var compensator (MSVC). Compared with traditional compensation methods, the EHCS makes full use of the SVC?s advantages of economy and reliability and of RPC?s advantages of technical capability and flexibility. Based on the idea of injecting a negative sequence, the compensation principle of the EHCS is analyzed in detail. Then the minimum installation capacity of an EHCS is theoretically deduced. Furthermore, a constraint optimization compensation strategy that meets national standards, which reduces compensation capacity further, is proposed. An experimental platform based on a digital signal processor (DSP) and a programmable logic controller (PLC) is built to verify the analysis. Simulated and experimental results are given to demonstrate the effectiveness and feasibility of the proposed method. @ The Author (s) 2016.
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceUnpaywall 20201031
dc.typeArticle
dc.contributor.departmentBIOCHEMISTRY
dc.description.doi10.1007/s40565-015-0179-y
dc.description.sourcetitleJournal of Modern Power Systems and Clean Energy
dc.description.volume4
dc.description.issue1
dc.description.page123-134
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
10_1007_s40565-015-0179-y.pdf1.8 MBAdobe PDF

OPEN

NoneView/Download

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons