Please use this identifier to cite or link to this item: https://doi.org/10.1021/acssuschemeng.8b05599
DC FieldValue
dc.titleComputational Design of 2D Covalent-Organic Framework Membranes for Organic Solvent Nanofiltration
dc.contributor.authorWEI WAN
dc.contributor.authorLiu, Jie
dc.contributor.authorJIANG JIANWEN
dc.date.accessioned2020-05-08T08:42:02Z
dc.date.available2020-05-08T08:42:02Z
dc.date.issued2019-01-07
dc.identifier.citationWEI WAN, Liu, Jie, JIANG JIANWEN (2019-01-07). Computational Design of 2D Covalent-Organic Framework Membranes for Organic Solvent Nanofiltration. ACS SUSTAINABLE CHEMISTRY & ENGINEERING 7 (1) : 1734-1744. ScholarBank@NUS Repository. https://doi.org/10.1021/acssuschemeng.8b05599
dc.identifier.issn2168-0485
dc.identifier.urihttps://scholarbank.nus.edu.sg/handle/10635/167850
dc.description.abstractCovalent-organic frameworks (COFs) are ordered crystalline materials covalently formed by building blocks of light elements. There has been increasing interest in the development of COF membranes for chemical separation. In this study, seven two-dimensional (2D) COF membranes are computationally designed with different functional groups and aperture sizes. By 245 sets of molecular simulations, the seven ultrathin COF membranes are investigated for organic solvent nanofiltration (OSN) of seven solvents (acetonitrile, acetone, methanol, ethanol, isopropyl alcohol, methyl ethyl ketone, and n-hexane) and four solutes (2,5-furandiamine, paracetamol, α-methylstyrene dimer, and Nile red). The solvent fluxes through the COF membranes are revealed to be governed by the aperture size and membrane functionality, as well as solvent properties. In general, the larger the aperture size, the higher is the flux. For membranes with comparable aperture size, the hydrophobic one exhibits higher fluxes than the hydrophilic counterpart for all the solvents except n-hexane. To elucidate this trend, solvent structures near the membranes are analyzed and the potentials of mean force for solvent permeation are evaluated. The solvent permeances through hydrophobic and hydrophilic membranes are correlated respectively with two different combinations of solvent properties. The solute rejection is found to depend on a complex interplay among solute size and polarity, solvent viscosity, solute-solvent interaction, aperture size and membrane functionality. In the presence of solutes, solvent permeances are reduced by approximately 10%. From the bottom-up, this comprehensive computational study provides quantitative insights into solvent permeation and solute rejection in the COF membranes, unravels the key governing factors, and would facilitate the development of new membranes for high-performance OSN.
dc.language.isoen
dc.publisherAmerican Chemical Society
dc.sourceElements
dc.subjectScience & Technology
dc.subjectPhysical Sciences
dc.subjectTechnology
dc.subjectChemistry, Multidisciplinary
dc.subjectGreen & Sustainable Science & Technology
dc.subjectEngineering, Chemical
dc.subjectChemistry
dc.subjectScience & Technology - Other Topics
dc.subjectEngineering
dc.subjectOrganic solvent nanofiltration
dc.subjectCovalent-organic frameworks
dc.subjectMolecular simulations
dc.subjectSolvent permeation
dc.subjectSolute rejection
dc.subjectFORCE-FIELD
dc.subjectTRANSPORT
dc.subjectDESALINATION
dc.subjectCRYSTALLINE
dc.subjectSEPARATION
dc.subjectFUTURE
dc.typeArticle
dc.date.updated2020-05-08T07:04:43Z
dc.contributor.departmentCHEMICAL & BIOMOLECULAR ENGINEERING
dc.description.doi10.1021/acssuschemeng.8b05599
dc.description.sourcetitleACS SUSTAINABLE CHEMISTRY & ENGINEERING
dc.description.volume7
dc.description.issue1
dc.description.page1734-1744
dc.published.statePublished
dc.grant.idNRF-CRP14-2014-01
dc.grant.idNRF-CRP17-2017-01
dc.grant.fundingagencyNational Research Foundation (NRF) Singapore
Appears in Collections:Staff Publications
Elements

Show simple item record
Files in This Item:
File Description SizeFormatAccess SettingsVersion 
8.pdfAccepted version3.22 MBAdobe PDF

OPEN

Post-printView/Download

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.