Please use this identifier to cite or link to this item:
https://doi.org/10.1039/d0ta00334d
DC Field | Value | |
---|---|---|
dc.title | Probing composition distributions in nanoalloycatalysts with correlative electron microscopy | |
dc.contributor.author | HE QIAN | |
dc.contributor.author | Shikai Liu | |
dc.contributor.author | Isla Gow | |
dc.contributor.author | Thomas Davies | |
dc.date.accessioned | 2020-04-30T03:16:34Z | |
dc.date.available | 2020-04-30T03:16:34Z | |
dc.date.issued | 2020-03-03 | |
dc.identifier.citation | HE QIAN, Shikai Liu, Isla Gow, Thomas Davies (2020-03-03). Probing composition distributions in nanoalloycatalysts with correlative electron microscopy. Journal of Materials Chemistry A 108 (845). ScholarBank@NUS Repository. https://doi.org/10.1039/d0ta00334d | |
dc.identifier.uri | https://scholarbank.nus.edu.sg/handle/10635/167468 | |
dc.description.abstract | Alloyed nanoparticles are important functional materials and have wide applications especially in heterogeneous catalysis and electrocatalysis. Controlled synthesis of nanoalloys is desirable in order to understand their structure–property relationships and further optimize their performance. While many synthesis methods have been developed, information on the resultant composition distributions among particles is often not available, and uniformity of composition from particle-to-particle is often incorrectly assumed. Such an analysis would require extensive work on a high-resolution analytical electron microscope, which has some drawbacks and the high-resolution equipment is not always readily accessible. We hereby introduce an alternative way for composition analysis of nanoalloys via a correlative electron microscopy approach, separating the size measurement (imaging) and composition analysis between TEM and SEM instruments. Using a case study of two AuPd nanoalloys which have very similar size distributions but significantly different composition distributions and catalytic activities, we demonstrate both the necessity of performing composition distribution analysis on ultrasmall nanoalloys and the feasibility of this method. We show that a more efficient X-ray analysis on nanoalloys can be done in an SEM due to intrinsically higher ionization cross-sections from the relatively lower energy (e.g. 20 keV) electron beam and the possibility of using large probe currents and X-ray detectors with large collection angles | |
dc.description.uri | https://pubs.rsc.org/en/content/articlelanding/2020/TA/D0TA00334D#!divAbstract | |
dc.language.iso | en | |
dc.publisher | Royal Society of Chemistry | |
dc.type | Article | |
dc.contributor.department | MATERIALS SCIENCE AND ENGINEERING | |
dc.description.doi | 10.1039/d0ta00334d | |
dc.description.sourcetitle | Journal of Materials Chemistry A | |
dc.description.volume | 108 | |
dc.description.issue | 845 | |
dc.published.state | Published | |
dc.grant.id | NRF-NRFF11-2019-0002 | |
dc.grant.fundingagency | National Research Foundation, Singapore | |
Appears in Collections: | Elements Staff Publications |
Show simple item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.