Please use this identifier to cite or link to this item: https://doi.org/10.1007/978-3-319-10404-1_20
DC FieldValue
dc.titleTensor total-variation regularized deconvolution for efficient low-dose CT perfusion
dc.contributor.authorFang R.
dc.contributor.authorSanelli P.C.
dc.contributor.authorZhang S.
dc.contributor.authorChen T.
dc.date.accessioned2018-08-21T04:55:02Z
dc.date.available2018-08-21T04:55:02Z
dc.date.issued2014
dc.identifier.citationFang R., Sanelli P.C., Zhang S., Chen T. (2014). Tensor total-variation regularized deconvolution for efficient low-dose CT perfusion. Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics) 8673 LNCS (PART 1) : 154-161. ScholarBank@NUS Repository. https://doi.org/10.1007/978-3-319-10404-1_20
dc.identifier.isbn9783319104034
dc.identifier.issn03029743
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/146087
dc.description.abstractAcute brain diseases such as acute stroke and transit ischemic attacks are the leading causes of mortality and morbidity worldwide, responsible for 9% of total death every year. 'Time is brain' is a widely accepted concept in acute cerebrovascular disease treatment. Efficient and accurate computational framework for hemodynamic parameters estimation can save critical time for thrombolytic therapy. Meanwhile the high level of accumulated radiation dosage due to continuous image acquisition in CT perfusion (CTP) raised concerns on patient safety and public health. However, low-radiation will lead to increased noise and artifacts which require more sophisticated and time-consuming algorithms for robust estimation. We propose a novel efficient framework using tensor total-variation (TTV) regularization to achieve both high efficiency and accuracy in deconvolution for low-dose CTP. The method reduces the necessary radiation dose to only 8% of the original level and outperforms the state-of-art algorithms with estimation error reduced by 40%. It also corrects over-estimation of cerebral blood flow (CBF) and under-estimation of mean transit time (MTT), at both normal and reduced sampling rate. An efficient computational algorithm is proposed to find the solution with fast convergence.
dc.publisherSpringer Verlag
dc.sourceScopus
dc.typeConference Paper
dc.contributor.departmentOFFICE OF THE PROVOST
dc.contributor.departmentDEPARTMENT OF COMPUTER SCIENCE
dc.description.doi10.1007/978-3-319-10404-1_20
dc.description.sourcetitleLecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
dc.description.volume8673 LNCS
dc.description.issuePART 1
dc.description.page154-161
dc.published.statepublished
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.