Please use this identifier to cite or link to this item:
https://scholarbank.nus.edu.sg/handle/10635/129247
DC Field | Value | |
---|---|---|
dc.title | A preliminary evaluation of serum proteins by capillary electrophoresis | |
dc.contributor.author | Wong, M.-S. | |
dc.contributor.author | Aw, T.-C. | |
dc.date.accessioned | 2016-11-02T03:18:29Z | |
dc.date.available | 2016-11-02T03:18:29Z | |
dc.date.issued | 1998-09 | |
dc.identifier.citation | Wong, M.-S.,Aw, T.-C. (1998-09). A preliminary evaluation of serum proteins by capillary electrophoresis. Journal of Capillary Electrophoresis and Microchip Technology 5 (5-6) : 217-221. ScholarBank@NUS Repository. | |
dc.identifier.issn | 10795383 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/129247 | |
dc.description.abstract | We evaluated the 5-band Serum Proteins by Capillary Electrophoresis kit (Bio-Rad Laboratories, Hercules, CA, U.S.A.) on the BioFocus 2000 CE (Bio-Rad) against conventional agarose gel electrophoresis (AGE) (Helena Laboratories, Beaumont, TX, U.S.A.). Serum from 60 patients was initially screened by AGE and divided into three groups: 1) normal electrophoretic pattern (n = 36, mean total protein 67.7 g/L), 2) monoclonal/oligoclonal gammopathy (n = 14, mean total protein 78.8 g/L), and 3) polyclonal gammopathy (n = 10, mean total protein 77.4 g/L). These samples were concurrently analyzed on the BioFocus 2000. Intraassay and interassay CVs for the five fractions for a normal sample were 0.17-1.44% and 0.42-9.11%, respectively, and 0.21-3.37% and 0.29-3.61%, respectively, for a sample with monoclonal gammopathy. Correlation coefficients for albumin and the albumin/globulin (A/G) ratio were 0.8891 (albumin range 17-93 g/L) and 0.8276 (A/G ratio range 0.39-7.81), respectively. The A/G ratio alone could not discriminate between the three groups. Capillary zone electrophoresis (CZE) correctly identified 33 of 36 samples in the normal group, and 22 of 24 samples in the other two groups, giving a clinical sensitivity and specificity of 91.7%. Our preliminary evaluation shows that protein separation by CZE is a simple, rapid, and automated alternative to conventional AGE. | |
dc.source | Scopus | |
dc.subject | Agarose gel electrophoresis | |
dc.subject | Capillary electrophoresis | |
dc.subject | Monoclonal bands | |
dc.subject | Serum proteins | |
dc.type | Article | |
dc.contributor.department | PATHOLOGY | |
dc.description.sourcetitle | Journal of Capillary Electrophoresis and Microchip Technology | |
dc.description.volume | 5 | |
dc.description.issue | 5-6 | |
dc.description.page | 217-221 | |
dc.identifier.isiut | NOT_IN_WOS | |
Appears in Collections: | Staff Publications |