Please use this identifier to cite or link to this item:
https://doi.org/10.1016/j.cca.2012.03.009
Title: | Current 25-hydroxyvitamin D assays: Do they pass the test? | Authors: | Ong, L. Saw, S. Sahabdeen, N.B. Tey, K.T. Ho, C.S. Sethi, S.K. |
Keywords: | 25OHD testing Accuracy Correlation Precision Vitamin D |
Issue Date: | 11-Jul-2012 | Citation: | Ong, L., Saw, S., Sahabdeen, N.B., Tey, K.T., Ho, C.S., Sethi, S.K. (2012-07-11). Current 25-hydroxyvitamin D assays: Do they pass the test?. Clinica Chimica Acta 413 (13-14) : 1127-1134. ScholarBank@NUS Repository. https://doi.org/10.1016/j.cca.2012.03.009 | Abstract: | Background: Vitamin D testing is becoming increasingly important with recent research demonstrating a correlation between vitamin D insufficiency and metabolic diseases, immunodeficiencies and other diseases. However, existing 25-hydroxyvitamin D (25OHD) assays lack comparability to the candidate reference method, causing difficulties in diagnosis and monitoring of vitamin D deficiency. Methods: We looked at the accuracy of 3 automated assays (Roche Diagnostics Elecsys® Total 25OHD assay, Abbott Architect® Total vitamin D assay, Advia Centaur® vitamin D Total assay) and Diasorin® Radioimmunoassay (RIA) compared to a routine laboratory Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS). Results: The correlation based on Passing Bablok regression was good with the slopes between 0.95 and 1.31 and the intercepts between - 3.24 and 3.68. However, a significant positive bias was observed using the Abbott Architect and the Diasorin RIA. Using published analytical goals of coefficient of variation (CV) < 10% and bias < 5%, most methods did not meet these criteria. Using measurement of uncertainty of 9%, most methods were able to meet criteria using quality control materials but not patient samples. Conclusion: Inadequacies of these assay performances are contributed by differences in method of extraction of vitamin D from vitamin D binding protein, cross-reactivities to 25OHD 2, 25OHD 3 and other vitamin D metabolites, matrix interferences and a lack of standardization. © 2012 Elsevier B.V. | Source Title: | Clinica Chimica Acta | URI: | http://scholarbank.nus.edu.sg/handle/10635/127129 | ISSN: | 00098981 | DOI: | 10.1016/j.cca.2012.03.009 |
Appears in Collections: | Staff Publications |
Show full item record
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.