Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.firesaf.2013.09.021
DC FieldValue
dc.titleFire behaviors of polymers under autoignition conditions in a cone calorimeter
dc.contributor.authorShi, L.
dc.contributor.authorChew, M.Y.L.
dc.date.accessioned2014-12-01T08:23:35Z
dc.date.available2014-12-01T08:23:35Z
dc.date.issued2013
dc.identifier.citationShi, L., Chew, M.Y.L. (2013). Fire behaviors of polymers under autoignition conditions in a cone calorimeter. Fire Safety Journal 61 : 243-253. ScholarBank@NUS Repository. https://doi.org/10.1016/j.firesaf.2013.09.021
dc.identifier.issn03797112
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/114003
dc.description.abstractBesides piloted ignition, autoignition is also an important aspect to real fire development as combustible materials may be ignited without independent flame. Fire behaviors of non-charring and charring polymers were then investigated in a cone calorimeter under autoignition conditions. Fire risk of non-charring polymers are higher than those of charring polymers because of high heat release, and the increase of heat release rate is much obvious with a higher heat flux or thickness. Charring polymers seem to have a higher CO yield, while non-charring polymers have a higher CO2 yield. Ignition methods have influences to combustion efficiency of non-charring polymers as effective heat of combustion under autoignition are observed lower than those reference data under piloted ignition conditions. Its influences to charring polymers are not obvious. Both CO and CO2 yields under flaming combustion are higher than those under non-flaming combustion, but mass percent of carbon seem to has limited effect. Experimental data in this study can provide a guidance to fire risk evaluation of non-charring and charring polymers. © 2013 Published by Elsevier Ltd.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/j.firesaf.2013.09.021
dc.sourceScopus
dc.subjectCone calorimeter
dc.subjectHeat release rate
dc.subjectMass loss rate
dc.subjectNon-charring polymer
dc.subjectSpontaneous ignition
dc.subjectThermal thickness
dc.typeArticle
dc.contributor.departmentBUILDING
dc.description.doi10.1016/j.firesaf.2013.09.021
dc.description.sourcetitleFire Safety Journal
dc.description.volume61
dc.description.page243-253
dc.description.codenFSJOD
dc.identifier.isiut000327365700026