Please use this identifier to cite or link to this item: https://doi.org/10.1016/S0168-583X(02)01537-9
DC FieldValue
dc.titleEdge-enhanced radiology with broadband synchrotron X-rays
dc.contributor.authorTsai, W.L.
dc.contributor.authorHsu, P.C.
dc.contributor.authorHwu, Y.
dc.contributor.authorJe, J.H.
dc.contributor.authorPing, Y.
dc.contributor.authorMoser, H.O.
dc.contributor.authorGroso, A.
dc.contributor.authorMargaritondo, G.
dc.date.accessioned2014-11-28T08:43:43Z
dc.date.available2014-11-28T08:43:43Z
dc.date.issued2003-01
dc.identifier.citationTsai, W.L., Hsu, P.C., Hwu, Y., Je, J.H., Ping, Y., Moser, H.O., Groso, A., Margaritondo, G. (2003-01). Edge-enhanced radiology with broadband synchrotron X-rays. Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms 199 : 436-440. ScholarBank@NUS Repository. https://doi.org/10.1016/S0168-583X(02)01537-9
dc.identifier.issn0168583X
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/113052
dc.description.abstractBroadband synchrotron X-rays with limited coherence can be used for high resolution phase contrast radiology. Our experimental results confirm the prediction that the extreme spatial coherence of third-generation synchrotron sources although helpful but not strictly necessary for refraction-based or diffraction-based edge enhancement. Source with rather limited lateral coherence can produce Fresnel diffraction fringes. The direct observation of the same fringes using broadband synchrotron lights demonstrates that high time coherence is also not required. Broadband light produces a high photon flux and high average photon energy, that was exploited for real-time radiology (5 ms frame) studies with high lateral resolution (1 μm) and excellent contrast, without using a sophisticated detecting system. These results enhance the potential impact of phase contrast on medical X-ray applications, materials science and other domains. © 2002 Elsevier Science B.V. All rights reserved.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1016/S0168-583X(02)01537-9
dc.sourceScopus
dc.subjectBroadband synchrotron light
dc.subjectPhase contrast imaging
dc.subjectRadiology
dc.typeConference Paper
dc.contributor.departmentSINGAPORE SYNCHROTRON LIGHT SOURCE
dc.description.doi10.1016/S0168-583X(02)01537-9
dc.description.sourcetitleNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
dc.description.volume199
dc.description.page436-440
dc.description.codenNIMBE
dc.identifier.isiut000180925400084
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.