Please use this identifier to cite or link to this item: https://doi.org/10.1167/iovs.09-3444
DC FieldValue
dc.titleRelationship of retinal vascular caliber with retinal nerve fiber layer thickness: The singapore malay eye study
dc.contributor.authorZheng, Y.
dc.contributor.authorCheung, N.
dc.contributor.authorAung, T.
dc.contributor.authorMitchell, P.
dc.contributor.authorHe, M.
dc.contributor.authorWong, T.Y.
dc.date.accessioned2014-11-26T07:47:37Z
dc.date.available2014-11-26T07:47:37Z
dc.date.issued2009
dc.identifier.citationZheng, Y., Cheung, N., Aung, T., Mitchell, P., He, M., Wong, T.Y. (2009). Relationship of retinal vascular caliber with retinal nerve fiber layer thickness: The singapore malay eye study. Investigative Ophthalmology and Visual Science 50 (9) : 4091-4096. ScholarBank@NUS Repository. https://doi.org/10.1167/iovs.09-3444
dc.identifier.issn01460404
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/109582
dc.description.abstractPURPOSE. To describe the relationship of retinal arteriolar and venular caliber with retinal nerve fiber layer (RNFL) thickness. METHODS. A population-based, cross-sectional study of Malay persons aged 40 to 80 years residing in Singapore was conducted from 2004 to 2006. Retinal arteriolar and venular calibers were measured with a computer-based technique according to a validated, standardized protocol. RNFL was assessed with retinal tomography. RESULTS. There were 2706 persons with gradable retinal photographs and HRT images of acceptable quality available for analysis. In linear regression models that adjusted for age, sex, diabetes, body mass index, intraocular pressure, and other factors, each standard deviation decrease in arteriolar and venular caliber was associated with a 5.81- and 8.37-μm decrease, respectively, in mean global RNFL thickness (both P
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1167/iovs.09-3444
dc.sourceScopus
dc.typeArticle
dc.contributor.departmentOPHTHALMOLOGY
dc.description.doi10.1167/iovs.09-3444
dc.description.sourcetitleInvestigative Ophthalmology and Visual Science
dc.description.volume50
dc.description.issue9
dc.description.page4091-4096
dc.description.codenIOVSD
dc.identifier.isiut000269438400009
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.