Please use this identifier to cite or link to this item: https://doi.org/10.1109/ICBPE.2009.5384072
DC FieldValue
dc.titleEnhancement of optic cup detection from ARGALI using key points
dc.contributor.authorWong, D.W.K.
dc.contributor.authorTan, N.M.
dc.contributor.authorLiu, J.
dc.contributor.authorTan, Z.
dc.contributor.authorTang, Y.
dc.contributor.authorZhang, Z.
dc.contributor.authorLim, J.H.
dc.contributor.authorNg, W.J.
dc.contributor.authorLi, H.
dc.contributor.authorLu, S.
dc.contributor.authorWong, T.Y.
dc.date.accessioned2014-11-25T09:48:13Z
dc.date.available2014-11-25T09:48:13Z
dc.date.issued2009
dc.identifier.citationWong, D.W.K.,Tan, N.M.,Liu, J.,Tan, Z.,Tang, Y.,Zhang, Z.,Lim, J.H.,Ng, W.J.,Li, H.,Lu, S.,Wong, T.Y. (2009). Enhancement of optic cup detection from ARGALI using key points. 2nd International Conference on Biomedical and Pharmaceutical Engineering, ICBPE 2009 - Conference Proceedings : -. ScholarBank@NUS Repository. <a href="https://doi.org/10.1109/ICBPE.2009.5384072" target="_blank">https://doi.org/10.1109/ICBPE.2009.5384072</a>
dc.identifier.isbn9781424447640
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/108608
dc.description.abstractWe propose a method for improving the accuracy of the optic cup detected from the ARGALI system. This method makes use of key points from the branching points of large vessels, the analysis of intensity variation and kinks from small vessels to obtain an enhanced optic cup. Measures used to assess the detection of the optic cup showed an 11% and 40% improvement in the mean average overlap and relative area difference respectively over the previous method. The difference in the CDR error was also shown to be reduced to less than 0.1CDR units. The improved optic cup detection is more consistent with the clinical ground truth, facilitating its use in ARGALI for mass screening for glaucoma for early detection to save sight. ©2009 IEEE.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1109/ICBPE.2009.5384072
dc.sourceScopus
dc.typeConference Paper
dc.contributor.departmentOPHTHALMOLOGY
dc.description.doi10.1109/ICBPE.2009.5384072
dc.description.sourcetitle2nd International Conference on Biomedical and Pharmaceutical Engineering, ICBPE 2009 - Conference Proceedings
dc.description.page-
dc.identifier.isiutNOT_IN_WOS
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.