Please use this identifier to cite or link to this item: https://doi.org/10.1002/jms.907
DC FieldValue
dc.titleSimultaneous determination of metformin and gliclazide in human plasma by liquid chromatography-tandem mass spectrometry: Application to a bioequivalence study of two formulations in healthy volunteers
dc.contributor.authorZhong, G.-P.
dc.contributor.authorBi, H.-C.
dc.contributor.authorZhou, S.
dc.contributor.authorChen, X.
dc.contributor.authorHuang, M.
dc.date.accessioned2014-10-29T01:58:35Z
dc.date.available2014-10-29T01:58:35Z
dc.date.issued2005-11
dc.identifier.citationZhong, G.-P., Bi, H.-C., Zhou, S., Chen, X., Huang, M. (2005-11). Simultaneous determination of metformin and gliclazide in human plasma by liquid chromatography-tandem mass spectrometry: Application to a bioequivalence study of two formulations in healthy volunteers. Journal of Mass Spectrometry 40 (11) : 1462-1471. ScholarBank@NUS Repository. https://doi.org/10.1002/jms.907
dc.identifier.issn10765174
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/106339
dc.description.abstractA rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated to simultaneously determine gliclazide and metformin in human plasma using huperzine A as the internal standard (IS). After acetonitrile-induced protein precipitation of the plasma samples, gliclazide, metformin and the IS were subjected to LC/MS/MS analysis using electro-spray ionization (ESI). Chromatographic separation was performed on a Hypersil BDS C18 column (50 mm × 2.1 mm, i.d., 3 μm). The method had a chromatographic running time of 2.0 min and linear calibration curves over the concentration ranges of 10-10 000 ng ml-1 for gliclazide and 7.8-4678.9 ng ml-1 for metformin. The recoveries of the method were found to be 71-104%. The lower limits of quantification (LOQ) of the method were 10.0 and 7.8 ng ml-1 for gliclazide and metformin, respectively. The intra- and interday precision was less than 15% for all quality control samples at concentrations of 100, 500, and 2000 ng ml -1. The validated LC/MS/MS method has been used to study bioequivalence in healthy volunteers. These results indicate that the method was efficient with a very short running time (2.0 min) for metformin and gliclazide compared to the methods reported in the literature. The presented method had acceptable accuracy, precision and sensitivity and was used in clinical bioequivalence study. Copyright © 2005 John Wiley & Sons, Ltd.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1002/jms.907
dc.sourceScopus
dc.subjectBioavailability
dc.subjectBioequivalence
dc.subjectGliclazide
dc.subjectLiquid chromatography/tandem mass spectrometry
dc.subjectMetformin
dc.subjectPharmacokinetics
dc.typeArticle
dc.contributor.departmentPHARMACY
dc.description.doi10.1002/jms.907
dc.description.sourcetitleJournal of Mass Spectrometry
dc.description.volume40
dc.description.issue11
dc.description.page1462-1471
dc.description.codenJMSPF
dc.identifier.isiut000233482400007
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.