Please use this identifier to cite or link to this item: https://doi.org/10.1080/10826076.2011.572215
DC FieldValue
dc.titleQuantification of trans-resveratrol in rat plasma by a simple and sensitive high performance liquid chromatography method and its application in pre-clinical study
dc.contributor.authorDas, S.
dc.contributor.authorNg, K.-Y.
dc.date.accessioned2014-10-29T01:57:42Z
dc.date.available2014-10-29T01:57:42Z
dc.date.issued2011-01
dc.identifier.citationDas, S., Ng, K.-Y. (2011-01). Quantification of trans-resveratrol in rat plasma by a simple and sensitive high performance liquid chromatography method and its application in pre-clinical study. Journal of Liquid Chromatography and Related Technologies 34 (14) : 1399-1414. ScholarBank@NUS Repository. https://doi.org/10.1080/10826076.2011.572215
dc.identifier.issn10826076
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/106280
dc.description.abstractThe intention of this study was to develop and validate a simple, sensitive, and accurate high performance liquid chromatography (HPLC) method for quantification of trans-resveratrol in rat plasma. Trans-resveratrol was recovered from plasma samples by liquid-liquid extraction. A reverse phase HPLC column was used and the assay was performed at 35°C through isocratic delivery (1mL·min -1) of acetonitrile and phosphate buffer solution, pH 7.0 (30:70v/v). UV absorbance was monitored at 320nm. Plasma samples were stable (>99%) at -80°C for 3 months. The recovery of trans-resveratrol from plasma was 95%. The HPLC method was validated. The retention times of trans-resveratrol and carbamazepine were 5.5 and 10.4min, respectively. The calibration curve was linear (R 2=0.9999) within the range of 5-1,000ng·mL -1. The lower limits of detection and quantification of trans-resveratrol were 2.5 and 5ng·mL -1, respectively. The intra-day and inter-day variations were
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1080/10826076.2011.572215
dc.sourceScopus
dc.subjectHPLC
dc.subjectliqid-liquid extraction
dc.subjectplasma
dc.subjecttrans-resveratrol
dc.subjectvalidation
dc.typeArticle
dc.contributor.departmentPHARMACY
dc.description.doi10.1080/10826076.2011.572215
dc.description.sourcetitleJournal of Liquid Chromatography and Related Technologies
dc.description.volume34
dc.description.issue14
dc.description.page1399-1414
dc.description.codenJLCTF
dc.identifier.isiut000296230900009
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.