Please use this identifier to cite or link to this item:
https://doi.org/10.1186/1471-2342-9-1
DC Field | Value | |
---|---|---|
dc.title | In-vivo optical detection of cancer using chlorin e6 - Polyvinylpyrrolidone induced fluorescence imaging and spectroscopy | |
dc.contributor.author | Chin, W.W.L. | |
dc.contributor.author | Thong, P.S.P. | |
dc.contributor.author | Bhuvaneswari, R. | |
dc.contributor.author | Soo, K.C. | |
dc.contributor.author | Heng, P.W.S. | |
dc.contributor.author | Olivo, M. | |
dc.date.accessioned | 2014-10-29T01:54:50Z | |
dc.date.available | 2014-10-29T01:54:50Z | |
dc.date.issued | 2009-01-08 | |
dc.identifier.citation | Chin, W.W.L., Thong, P.S.P., Bhuvaneswari, R., Soo, K.C., Heng, P.W.S., Olivo, M. (2009-01-08). In-vivo optical detection of cancer using chlorin e6 - Polyvinylpyrrolidone induced fluorescence imaging and spectroscopy. BMC Medical Imaging 9 : -. ScholarBank@NUS Repository. https://doi.org/10.1186/1471-2342-9-1 | |
dc.identifier.issn | 14712342 | |
dc.identifier.uri | http://scholarbank.nus.edu.sg/handle/10635/106090 | |
dc.description.abstract | Background: Photosensitizer based fluorescence imaging and spectroscopy is fast becoming a promising approach for cancer detection. The purpose of this study was to examine the use of the photosensitizer chlorin e6 (Ce6) formulated in polyvinylpyrrolidone (PVP) as a potential exogenous fluorophore for fluorescence imaging and spectroscopic detection of human cancer tissue xenografted in preclinical models as well as in a patient. Methods: Fluorescence imaging was performed on MGH human bladder tumor xenografted on both the chick chorioallantoic membrane (CAM) and the murine model using a fluorescence endoscopy imaging system. In addition, fiber optic based fluorescence spectroscopy was performed on tumors and various normal organs in the same mice to validate the macroscopic images. In one patient, fluorescence imaging was performed on angiosarcoma lesions and normal skin in conjunction with fluorescence spectroscopy to validate Ce6-PVP induced fluorescence visual assessment of the lesions. Results: Margins of tumor xenografts in the CAM model were clearly outlined under fluorescence imaging. Ce6-PVP-induced fluorescence imaging yielded a specificity of 83% on the CAM model. In mice, fluorescence intensity of Ce6-PVP was higher in bladder tumor compared to adjacent muscle and normal bladder. Clinical results confirmed that fluorescence imaging clearly captured the fluorescence of Ce6-PVP in angiosarcoma lesions and good correlation was found between fluorescence imaging and spectral measurement in the patient. Conclusion: Combination of Ce6-PVP induced fluorescence imaging and spectroscopy could allow for optical detection and discrimination between cancer and the surrounding normal tissues. Ce6-PVP seems to be a promising fluorophore for fluorescence diagnosis of cancer. © 2009 Chin et al; licensee BioMed Central Ltd. | |
dc.description.uri | http://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1186/1471-2342-9-1 | |
dc.source | Scopus | |
dc.type | Article | |
dc.contributor.department | PHARMACY | |
dc.description.doi | 10.1186/1471-2342-9-1 | |
dc.description.sourcetitle | BMC Medical Imaging | |
dc.description.volume | 9 | |
dc.description.page | - | |
dc.description.coden | BMIMA | |
dc.identifier.isiut | NOT_IN_WOS | |
Appears in Collections: | Staff Publications Elements |
Show simple item record
Files in This Item:
File | Description | Size | Format | Access Settings | Version | |
---|---|---|---|---|---|---|
2009-in-vivo_optical_detection_cancer_using-pub.pdf | 3.76 MB | Adobe PDF | OPEN | Published | View/Download |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.