Please use this identifier to cite or link to this item: https://doi.org/10.1002/jssc.201000922
DC FieldValue
dc.titleExtraction of ketamine from urine using a miniature silica monolithic cartridge followed by quantification with liquid chromatography tandem mass spectrometry (LC-MS/MS)
dc.contributor.authorNema, T.
dc.contributor.authorChan, E.C.Y.
dc.contributor.authorHo, P.C.
dc.date.accessioned2014-10-29T01:52:57Z
dc.date.available2014-10-29T01:52:57Z
dc.date.issued2011-05
dc.identifier.citationNema, T., Chan, E.C.Y., Ho, P.C. (2011-05). Extraction of ketamine from urine using a miniature silica monolithic cartridge followed by quantification with liquid chromatography tandem mass spectrometry (LC-MS/MS). Journal of Separation Science 34 (9) : 1041-1046. ScholarBank@NUS Repository. https://doi.org/10.1002/jssc.201000922
dc.identifier.issn16159306
dc.identifier.urihttp://scholarbank.nus.edu.sg/handle/10635/105952
dc.description.abstractThe high surface area monolith with reactive hydroxyl group on its surface enables it to function as a miniature solid-phase extraction (SPE) cartridge in size of 1 cm in diameter and 0.5 cm in length. The prepared silica monolith was characterized by Brunauer-Emmett-Teller method, scanning electron microscopy, X-ray diffraction and Fourier transform infrared (FTIR) spectroscopy. Ketamine was selected as model analyte to validate the extraction efficiency of the prepared cartridge. The extracted ketamine from urine sample was quantitated by liquid chromatography tandem mass spectrometry (LC-MS/MS) using positive electrospray ionization. The limit of detection and quantification for ketamine was found to be 0.5 and 1.6 ng/mL, respectively. The analysis exhibited linearity in the range of 10-500 ng/mL with coefficient of correlation >0.99. The recovery was found to be in the range of 89-107% with relative standard deviation (RSD) less than 10%. The prepared cartridge was found robust in extracting ketamine efficiently and repeatedly without any significant deterioration in its performance. Moreover, the batch-to-batch variations in the performance of the prepared cartridges in terms of % ion suppression of the extracts and recoveries of samples were small, suggesting the consistency in the properties of the monolith. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
dc.description.urihttp://libproxy1.nus.edu.sg/login?url=http://dx.doi.org/10.1002/jssc.201000922
dc.sourceScopus
dc.subjectKetamine
dc.subjectLC-MS/MS
dc.subjectSilica monolithic cartridge
dc.subjectSPE
dc.typeArticle
dc.contributor.departmentPHARMACY
dc.description.doi10.1002/jssc.201000922
dc.description.sourcetitleJournal of Separation Science
dc.description.volume34
dc.description.issue9
dc.description.page1041-1046
dc.description.codenJSSCC
dc.identifier.isiut000290634600011
Appears in Collections:Staff Publications

Show simple item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.