Please use this identifier to cite or link to this item: https://doi.org/10.1002/jms.1966
Title: Efficiency of a miniaturized silica monolithic cartridge in reducing matrix ions as demonstrated in the simultaneous extraction of morphine and codeine from urine samples for quantification with liquid chromatography-tandem mass spectrometry (LC-MS/MS)
Authors: Nema, T.
Chan, E.C.Y. 
Ho, P.C. 
Keywords: codeine
LC-MS/MS
morphine
silica monolithic cartridge
solid phase extraction
urine
Issue Date: Sep-2011
Citation: Nema, T., Chan, E.C.Y., Ho, P.C. (2011-09). Efficiency of a miniaturized silica monolithic cartridge in reducing matrix ions as demonstrated in the simultaneous extraction of morphine and codeine from urine samples for quantification with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Journal of Mass Spectrometry 46 (9) : 891-900. ScholarBank@NUS Repository. https://doi.org/10.1002/jms.1966
Abstract: Presence of matrix ions could negatively affect the sensitivity and selectivity of liquid chromatography-tandem mass spectrometer (LC-MS/MS). In this study, the efficiency of a miniaturized silica monolithic cartridge in reducing matrix ions was demonstrated in the simultaneous extraction of morphine and codeine from urine samples for quantification with LC-MS. The miniaturized silica monolith with hydroxyl groups present on the largely exposed surface area function as a weak cation exchanger for solid phase extraction (SPE). The miniaturized silica cartridge in 1 cm diameter and 0.5 cm length was housed in a 2-ml syringe fixed over a SPE vacuum manifold for extraction. The cleaning effectiveness of the cartridge was confirmed by osmometer, atomic absorption spectrometer, LC-MS and GC-TOFMS. The drugs were efficiently extracted from urine samples with recoveries ranging from 86% to 114%. The extracted analytes, after concentration and reconstitution, were quantified using LC-MS/MS. The limits of detection for morphine and codeine were 2 ng/ml and 1 ng/mL, respectively. The relative standard deviations of measurements ranged from 3% to 12%. The monolithic sorbent offered good linearity with correlation coefficients > 0.99, over a concentration range of 50-500 ng/ml. The silica monolithic cartridge was found to be more robust than the particle-based packed sorbent and also the commercial cartridge with regards to its recyclability and repeated usage with minimal loss in efficiency. Our study demonstrated the efficiency of the miniaturized silica monolith for removal of matrix ions and extraction of drugs of abuse in urinary screening. © 2011 John Wiley & Sons, Ltd.
Source Title: Journal of Mass Spectrometry
URI: http://scholarbank.nus.edu.sg/handle/10635/105911
ISSN: 10765174
DOI: 10.1002/jms.1966
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.