Please use this identifier to cite or link to this item: https://doi.org/10.1039/b9ay00300b
Title: Simultaneous electrochemical detection of carcinogenic polycyclic aromatic amines in environmental samples using single-walled carbon nanotube-gold nanoparticle composite
Authors: George, S.
Lee, H.K. 
Issue Date: Apr-2010
Citation: George, S., Lee, H.K. (2010-04). Simultaneous electrochemical detection of carcinogenic polycyclic aromatic amines in environmental samples using single-walled carbon nanotube-gold nanoparticle composite. Analytical Methods 2 (4) : 326-334. ScholarBank@NUS Repository. https://doi.org/10.1039/b9ay00300b
Abstract: A nanocomposite was prepared using single walled carbon nanotubes (SWCNTs) and thiol-derivatised gold nanoparticles (Aunano). Transmission electron microscopy (TEM) image of the nanocomposite showed that the Au nano were self-assembled on to the side walls of the SWCNTs after the modification process. Moreover, from the TEM analysis, it was clear that the likelihood of agglomeration of these nanoparticles in the nanocomposite were rare. A film of the nanocomposite was then applied on a glassy carbon electrode (GCE). The nanocomposite modified GCE was used for the electrochemical detection of several carcinogenic polycyclic aromatic amines (PAAs) simultaneously. The combination of the adsorptive properties of SWCNTs with an enhanced electroactive surface area, electrical conductivity of Aunano, together with the interaction of the amino group of the analytes and Au nano permitted very efficient detection of the analytes. Preconcentration and detection of the analytes in the real samples could be achieved in a single step using adsorptive stripping voltammetry (ASV). ASV for the PAAs achieved detection limits in the range of 1 μg L-1 (using 9,10-diaminophenanthrene as an example), with linearity up to 3 orders of magnitude. Moreover, the nanocomposite modified electrode exhibited excellent selectivity with high reproducibility towards several PAAs and resulted in their simultaneous and sensitive detection with detection limits in the μg L -1 range. Using 9,10-diaminophenanthrene as an example, the reproducibility of the analyte signal in the simultaneous detection of several PAAs was determined to be within 5% (n = 8) from one electrode preparation to another, and the response signal was stable (±4.5% at 95% confidence interval) for 15 repeated analyses with 600 s of preconditioning. Applicability of the procedure to tap water, river water, and wastewater samples was demonstrated. Such nanocomposite devices hold great promise for convenient and sensitive environmental screening of carcinogenic PAAs. © 2010 The Royal Society of Chemistry.
Source Title: Analytical Methods
URI: http://scholarbank.nus.edu.sg/handle/10635/94810
ISSN: 17599660
DOI: 10.1039/b9ay00300b
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.