Title: Performance of co/counter-current and counter/co-current flow patterns in an internally staged permeator for gas separation
Authors: Chen, Y.S.
Li, K. 
Teo, W.K. 
Issue Date: Jul-1995
Citation: Chen, Y.S.,Li, K.,Teo, W.K. (1995-07). Performance of co/counter-current and counter/co-current flow patterns in an internally staged permeator for gas separation. Chemical Engineering Research and Design 73 (A5) : 567-574. ScholarBank@NUS Repository.
Abstract: Mathematical models have been developed for an internally two-staged hollow fibre permeator for the cases of co/counter-current and counter/co-current flow patterns. A comparative study on the performance of these two flow patterns together with two other flow patterns, i.e. cocurrent flow and countercurrent flow, has been conducted using gas mixtures of O2/N2 and CO2/N2. It has been shown, both theoretically and experimentally, that in terms of achieving a higher permeate enrichment, the co/counter-current mode is always the most efficient one followed by cocurrent flow, while the counter/co-current and countercurrent flow patterns are less efficient. The experimental results are generally in good agreement with theoretical predictions.