Please use this identifier to cite or link to this item: https://doi.org/10.1016/j.snb.2013.03.053
Title: Plasmonic nanohole arrays for monitoring growth of bacteria and antibiotic susceptibility test
Authors: Kee, J.S.
Lim, S.Y.
Perera, A.P.
Zhang, Y. 
Park, M.K.
Keywords: Antibiotic susceptibility test
Bacteria growth monitoring
Escherichia coli
Nanoholes
Optical biosensor
Surface plasmons
Issue Date: 2013
Citation: Kee, J.S., Lim, S.Y., Perera, A.P., Zhang, Y., Park, M.K. (2013). Plasmonic nanohole arrays for monitoring growth of bacteria and antibiotic susceptibility test. Sensors and Actuators, B: Chemical 182 : 576-583. ScholarBank@NUS Repository. https://doi.org/10.1016/j.snb.2013.03.053
Abstract: Rapid and sensitive detections of the growth of bacteria are essential assay procedures in the food industry, water and environment control and clinical diagnosis. Here, we present a plasmonic nanohole sensor for rapid, sensitive and quantitative monitoring of the bacterial growth and antibiotic susceptibility test. The concept is based on extraordinary optical transmission (EOT) phenomenon in plasmonic nanohole and employs Escherichia coli specific antibody for bacteria capturing. The challenge lies in detecting the much larger dimension of E. coli with the smaller penetration depths of the electromagnetic field. The plasmonic nanohole array was fabricated using mask-based deep ultraviolet (DUV) lithography method and characterized for bulk refractive index sensitivity and surface mass sensitivity. After gold-specific surface modification and antibody immobilization, bacteria were effectively captured and grown on the sensor surface. The sensor platform with temperature-controlled environment was successfully tested for monitoring the growth of E. coli. The plasmonic nanohole sensor has immense potential for clinical diagnosis such as rapid determination of pathogen susceptibility test; with bulk refractive index sensitivity of 406.4 nm/RIU and surface mass sensitivity of ~1.802 ng/mm 2. We explored the capability of the sensor to provide sensitive monitoring of low bacterial quantity (
Source Title: Sensors and Actuators, B: Chemical
URI: http://scholarbank.nus.edu.sg/handle/10635/88041
ISSN: 09254005
DOI: 10.1016/j.snb.2013.03.053
Appears in Collections:Staff Publications

Show full item record
Files in This Item:
There are no files associated with this item.

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.