Please use this identifier to cite or link to this item: https://doi.org/10.1016/0010-7824(92)90133-E
Title: Effect of Norplant®-2 rods on haemostatic function
Authors: Singh, K. 
Viegas, O.A.C. 
Koh, C.L.S. 
Ratnam, S.S. 
Issue Date: 1992
Citation: Singh, K., Viegas, O.A.C., Koh, C.L.S., Ratnam, S.S. (1992). Effect of Norplant®-2 rods on haemostatic function. Contraception 46 (1) : 71-81. ScholarBank@NUS Repository. https://doi.org/10.1016/0010-7824(92)90133-E
Abstract: A longitudinal study on one-hundred Singaporean women using Norplant®-2 rod implant for contraception and their effects on the haemostatic function was carried out. There was a decrease in vitamin K-dependent Factors II, VII and a tendency towards lowered fibrinolytic activity after prolonged use of Norplant®-2 rods. The results indicate that the Norplant®-2 rod implant system does not contribute towards hypercoagulable state but increased platelets and accelerated platelet aggregation observed will require further study to ascertain whether there is a concomitant increase in platelet activation.
Source Title: Contraception
URI: http://scholarbank.nus.edu.sg/handle/10635/36908
ISSN: 00107824
DOI: 10.1016/0010-7824(92)90133-E